4
Installation
Electrical installation
Operating instructions – ECDriveS
®
25
4.2.5
Wiring diagrams
For the terminal assignment of the feed-in terminal and the I/O terminal strip, refer to
chapter "Terminal designation" (→
PNP module with RUN/REVERSE wiring
ECC-DBC-24-00
2
1
4
3
6
5
8
7
10
9
DC 24 V
19886800779
As a requirement for the direction of rotation reversal using the "reverse" input, "RUN
A" or "RUN B" must be activated.
Observe that the roller drive must be stopped before the direction of rotation is re-
versed.
PNP module with error output wiring
ECC-DBC-24-00
2
1
4
3
6
5
8
7
10
9
[1]
19886797835
[1]
Max. 100 mA
For this connection, the current must not exceed 100 mA. If the device connected with
the error output requires a higher current, an interface relay must be used in between.
28507088/EN – 11/2018