ECShell engineering software
Manual
– ECC-DFC field bus controller
63
If the “Ignore Jam Sensor” check box has been activated, when the sensor is
clear again, this 5-second delay is not used and the zone immediately switches
back to automatic normal operation as soon as the sensor is clear.
A similar situation applies to the Arrival Jam: If a load is moving from the up-
stream to the downstream zone, the logic expects it to arrive in the downstream
zone within the time set in the Jam Timer.
If the load does not arrive within this time window, an Arrival Jam is indicated.
Once the Arrival Jam has been determined, the zone is released again by default
when the time value set in the Jam Timer has elapsed. If the “Ignore Arrival Jam”
check box is activated, the logic does not wait for the additional delay time and
the Arrival Jam Status is automatically reset immediately after it has been deter-
mined.
If one or both check boxes are activated, the logic of the zone ignores the reset
delay for the respective jam status.
8.4.6.
Motor roller settings
The
two biggest areas of the main window are for “Left Zone” and “Right Zone”.
They display settings for the motor rollers and the overall status. They also allow
you to modify the motor settings.
Motor type
The “Motor Type” drop-down menu contains all motor brands and models whose
profiles are available for ECC-
DFC. “ECR_Boost” is the default setting after the
auto configuration procedure has been carried out. The new settings are down-
loaded to the selected node.
Clicking “Set All” downloads the selected setting to the left-hand zones of all
modules that are in the vicinity of the node entered above in the main window
(“Node No”). If values of 5 and 12 have been entered in the “Node No” fields, for
example, the choice in the “Motor Type” drop-down menu leads to a change to
node 5, and clicking “Set All” changes nodes 6 to 12 to the same setting as node
5.
Содержание ECDriveS ECC-DFC
Страница 2: ...SEW EURODRIVE Driving the world ...
Страница 73: ...ECShell engineering software Manual ECC DFC field bus controller 73 ...
Страница 89: ...Appendix A Dimensions and Installation Instructions Manual ECC DFC field bus controller 89 Dimensions in mm ...
Страница 94: ......
Страница 95: ......