Status displays
Manual
– ECC-DFC field bus controller
29
6.3.
Motors
Indication
Position
LED status
Description
Left motor
and right motor
2 and 3
Off
Motor not running and no error found
Illuminated
in
green
Connection has been established
Illuminated
in
red
If motor is running: Indicates current limiting.
If the motor is in the idle state: Indicates that the motor is not
correctly connected or is running hot
Voltage supply is less than 18 V or above 30 V
Slow
flashing
in red
Motor is overloaded and ECC-DFC is limiting the current in
order to lower the temperature
Fast flashing in
red
Motor short circuit detected between at least two of the phase
windings
6.4.
Sensors
Indication
Position
LED status
Description
Sensors
4 and 5
Illuminated in yellow
ECC-DFC starting up
Illuminated in green
Sensor input activated
Illuminated in red
Sensor status signal
Slow flashing in red
Zone congestion or missing sensor
Fast flashing in red
Network stop status
6.5.
Power
Indication
Position
LED status
Description
Power
1
Illuminated in blue Current supply for logic and motors is con-
nected
Slow flashing in
blue
Motor voltage is less than 18 V