ECShell engineering software
Manual
– ECC-DFC field bus controller
47
If the PC is configured so that it auto-
matically receives an IP address, all
you need to do is connect the PC as
shown in figure 18. The IP address of
the PC is configured so that the EC-
Shell engineering software can be
used.
Manual methods for configuring the IP addresses
With bigger system configurations with several subnetworks and/or systems to
which a certain PC is to be connected without interruption, manual configuration
of the IP address of the PC is preferable.
If several subnetworks of the fieldbus controller share the same physical Ethernet
cabling (directly or via Ethernet switches), it is advisable for the subnetworks to
be defined and for each auto configuration master to have its subnetwork as-
signed before carrying out the auto configuration procedures.
Since all of the subnetworks that are required have already been defined, the PC
can set its IP address and subnet mask accordingly so that you can access all
subnetworks of the fieldbus controller from a single PC with the ECShell engi-
neering software.
Regardless of which manual procedure you have chosen, you can always com-
plete it with the PC and ECShell.
Use of ECShell for localizing the auto configuration master
Every manual method for configuring the IP address requires access to the IP
address of the auto configuration master with the aid of the ECShell engineering
software.