![Sesamo LIGHT MILLENIUM Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/sesamo/light-millenium/light-millenium_installation-instruction_1247160019.webp)
* NA = Normally open NC = Normally closed
The electrical signal from external peripherals can be varied through the advanced selector or PC connection: from nor-
mally closed to normally open and vice versa. See the advanced selector used manual for further details.
G. Connector for PC - unit connections
A PC connection board (optional) is required to connect the MILLENNIUM unit to a Personal Computer.
The following is possible with MILLENNIUMWARE software:
• Advanced adjustments of some operating parameters
• Diagnostics and advanced information on unit status
• Microprocessor programming
PC connection board
Fig. 37
Installation Instruction
19
LIGHT MILLENNIUM
SIGNAL
COM
SAFE CLOSE
AUX IN
AUX OUT
SAFE OPEN
KEY
START 1
START2
TYPE*
NC
NA
NA
NC
NA
NA
DESCRIPTION
Common electrical signal.
Signal for the connection of an external
photocell or safety control device for
wing closing
.
Auxiliary input signal. Auxiliary devices
can be connected to this signal. It is
normally used for inter lock functions.
Auxiliary output signal, PNP transistor
type for particular door condition sig-
nals (reset, open, closed, etc).
Signal for the connection of sensors for pro-
tection during wing opening.
Lock signal. Closure devices can be
connected such as electronic key, key
selector, transponder, etc.
The signal can be controlled in bi or
mono-stabile mode with an activation
time equal to about 500 msec. For
mode type selection see paragraph
JUMPERS.
Opening signal. Wing opening devices
can be connected.
Opening signal. Wing opening devices
can be connected.
FUNCTION
If the door is closing and the contact opens, the unit sends and
immediate motion inversion command. Closing will only recom-
mence after the contact closes.
The signal must be short circuited with COM if not devices
(internal or external) are connected.
When used as an auxiliary signal the function logic can be
personalised according to customer requests.
When used as inter lock logic, closing this signal inhibits door
functions that will not open even with open signal presence.
According to the type chosen signal, the output becomes
active (12Vdc and led on) when the door is in the set condi-
tion (Reset, open, closed, etc). See the advanced selector
manual for further details.
If the door is opening and the contact closes, the unit sends an
immediate movement stop command. Opening will only contin-
ue after this signal is deactivated.
If the signal opens the unit sends a complete wing closure
command (from any position) From this moment until the sig-
nal is closed the door stays in this position and no external
peripheral is detected (including multi-logic selectors). As
soon as the signal closes the door opens permitting access.
The signal must be short circuited with COM if no devices
are connected.
Closing this signals causes the wings to open. This signal is
only monitored in 2 Radar logic.
Closing this signals causes the wings to open. This signal is
monitored in both 2 Radar and 1 Radar logic.
Содержание LIGHT MILLENIUM
Страница 1: ...Automatisms for sliding doors I N S T A L L A T I O N I N S T R U C T I O N...
Страница 2: ...2...
Страница 23: ...23...