13
Installation and Service Manual
INSTALLATION
RECIRCULATION LINES AND PUMP
1A
1C
1D
1B
1F
1G
1E
FIGURE 1
1.
If required secure recirculation pump (
1A
) to counter
or under counter that unit is installed on (
See Figure
1
). Run insulated beverage line (
1B
) from the barded
pump outlet fitting up to the right barbed cooling coil
inlet (
2A
) on back of dispenser and secure both ends
of line to the barbed fittings with otiker clamps (
See
Figures 1 and 2
). Connect another insulated bever-
age line to left barbed cooling coil outlet (
2B
) on back
of dispenser and secure line to barbed fitting with otiker
clamp (
See Figure 2
).
2.
Wrap cork tape insulation around the barbed inlets
(
3A
) and insulated beverage lines (
3B
) as shown (
See
Figure 3
).
Installation of cork tape must be done
properly to prevent condensation and tempera-
ture gain of circulating water.
3.
Route insulated beverage line from the cooling coil
outlet (
2B
) up through either the back or bottom of
tower (
4A
) as shown (
See Figures 2 and 4
). Route
insulated beverage line through left side hole in the
valve mount plate (
4B
) as shown (
See
Figure 4
).
Connect insulated beverage line to left side of barb
fitting (
4C
) and secure line to barbed fitting with otiker
clamp (
See Figure 4
). Connect the last insulated
beverage line to right side of barbed fitting (
4E
) and
secure line to barbed fitting with otiker clamp (
See
Figure 4
). Wrap fitting and insulated beverage lines
(
4D
) with cork tape insulation (
See Figure 4
).
Instal-
lation of cork tape must be done properly to pre-
vent condensation and temperature gain of
cir-
culating water
.
4.
Chiller Installations:
When using a refrigerated
chiller (
5A
) for cooling plain water supplied to tower
the recirculation pump can be mounted to the exte-
rior cabinet of chiller (
See Figure 5
)..
5.
Chiller Installations:
Attach insulated beverage line
(
1B
) to the pump outlet fitting and secure with otiker
clamp. Then run insulated line (
1B
) to the plain water
coil inlet (
5B
) of the chiller (
5A
). Secure line to the coil
inlet (
5B
) of the chiller (
5A
) mechanically. If applicable
us an otiker clamp (
See Figures 1 and 5
).
6.
Chiller Installations:
Connect another insulated bev-
erage line to the plain water coil outlet (
5C
) of the
chiller (
5A
). Secure line to the coil outlet (
5C
) of the
chiller (
5A
) mechanically. If applicable us an otiker
clamp (
See Figure 5
).
FIGURE 2
FIGURE 3
2A
2B
3A
3B
PARTS INCLUDED IN KIT NO: 020000783
Qty.
Description
Part Number
1
Recirculation pump/w/fittings
020000780
3
Line insulated beverage
020000781
1
Instructions Recirculation lines 020000782
10
Clamp Otiker 15.7
15.7-706R
6ft
Tape Cork Insulation
RM051120
Содержание FlexTower 12
Страница 21: ...21 Installation and Service Manual OPERATION SPECIFICATIONS Serial Plate Serial Plate SERIAL PLATE...
Страница 32: ...32 Installation and Service Manual EXPLODED VIEWS PARTS DIAGRAMS POWER SUPPLY WIRING...
Страница 34: ...34 Installation and Service Manual EXPLODED VIEWS PARTS DIAGRAMS FLEXTOWER EXPLODED VIEW...
Страница 37: ......
Страница 38: ......