Unit Installation
COUNTER SEALING
In order for all CEV units to comply with NSF requirements
within the United States, the CEV base must be sealed to
the countertop unless the optional 4” legs are installed. All
access holes to the base must be sealed. If the 4” legs are
installed, proceed to Filling the Water Tank, otherwise
proceed as follows to seal the CEV base:
A. Tilt CEV up to expose bottom of base.
B. Remove the 2 plastic tubes under the CEV.
C. Liberally apply silastic sealant such as Dow
Corning RTV 731 or equivalent on the base
bottom edges.
D. Lower the CEV into operating position on the
counter top to complete the seal of the base to
the countertop.
NOTE: Do not move CEV after positioning or the seal
between the base and the countertop will be broken.
E. Apply additional sealant around the bottom of
the base. The seal must be a minimum of 1/4
inch to prevent crevices and to ensure a
complete seal.
FILLING THE WATER TANK
1. Make sure the plug in the water tank drain hose is
secure.
2. Remove the plug from the water fill hole located on
the carbonator pump deck. Fill the water tank with
clean water until water flows out of the tank overflow.
Use a funnel if necessary. Caution: Be careful not to
spill water on any electrical fitting or connection. Do
not use distilled water.
NOTE: An alternative method to fill the water tank would
be to temporarily splice the incoming water line into the
water tank drain hose, turn on the water and fill the tank
until water comes out the overflow drain. Turn off the
water and plug the water tank drain hose.
3. Install plug in water fill hole.
4. Place CEV power switch, compressor switch and
the carbonator switch, located on the front of the
control box, in “OFF” position.
NOTE: Complete control box instructions may be found
in the Electronic Ice & Carbonation Control section.
!
Warning
CEV must be electrically grounded to avoid possible fatal
electrical shock or serious injury to the operator. 120V CEV
power cord is equipped with a three-prong plug. If supply
cord is damaged it must be replaced by the manufacturer or
its service agent or a similarly qualified person in order to
avoid a hazard. If a grounded electrical outlet is not
available, use an approved method to ground the CEV.