Installation, Use & Care Manual

This manual is updated as new information and models are released.

Visit our website for the latest manual. www.manitowocfsg.com

Leader in Ice & Beverage Dispensers

CEV SERIES

Beverage Dispensers

Part Number 020004000

10/13

Содержание CEV SERIES

Страница 1: ...nual This manual is updated as new information and models are released Visit our website for the latest manual www manitowocfsg com Leader in Ice Beverage Dispensers CEV SERIES Beverage Dispensers Par...

Страница 2: ...sure to read the Warning statement before proceeding and work carefully Caution Text in a Caution box alerts you to a situation in which you could damage the equipment Be sure to read the Caution sta...

Страница 3: ...Location 2 8 Electrical 2 9 General 2 9 Minimum Circuit Ampacity 2 9 Electrical Requirements 2 9 Voltage 2 9 Minimum Circuit Amperage Chart 2 9 Refrigerant 2 9 Grounding Instructions 2 9 Unit Installa...

Страница 4: ...3 4 Figal Tanks 3 4 Racking 3 4 B I B 3 4 Pumps 3 4 Auto Bag Selectors 3 4 Operation Checks and Adjustments 3 5 Electronic Ice and Carbonation Control 3 5 Section 4 Maintenance Cleaning 4 1 Daily Clea...

Страница 5: ...__ Service Agent Telephone Number _________________ Your Local MBE Distributor ______________________ Distributor Telephone Number ____________________ Model Number _______________________________ Ser...

Страница 6: ...specifically excludes all beverage valve brixing general adjustments cleaning accessories and related servicing Your warranty card must be returned to MBS to activate the warranty on this equipment I...

Страница 7: ...nt for information regarding start up services Typical CEV Series Internal Carbonation Beverage Dispensing System Typical CEV External Carbonation Ambient Beverage Dispensing System Important Failure...

Страница 8: ...x System Figal system also CO2 regulator set Product connectors for Figal tank Gas connectors for Figal tank Beverage dispenser Beverage tubing CO2 tank Figal beverage tanks Stepless Oetiker clamps Ch...

Страница 9: ...r Bulk tank Bulk syrup tanks Do you have enough space to install the dispenser or a dispenser and top mounted cuber Does top mounted cuber if utilized have a minimum of 6 inches 15 3 cm clearance on a...

Страница 10: ...in Water tank overflow hose goes into the drain pan PLACING UNIT IN THE OPERATING POSITION The CEV must be level horizontally from right to left and front to rear CEV inlet supply lines power cord and...

Страница 11: ...cm 11 76 29 8 cm 4 44 11 3 cm N A N A 25 75 65 4 cm 17 00 43 1 cm 17 50 44 4 cm CEV 40 29 88 75 9 cm 26 00 66 0 cm 11 76 29 8 cm 4 44 11 3 cm N A N A 25 75 65 4 cm 17 00 43 1 cm 23 00 58 4 cm B C D G...

Страница 12: ...art Number 020004000 10 13 Footprints CEV30 FOOTPRINT Caution Cutting the countertop may decrease its strength Counter should be braced to support the dispenser countertop weight plus ice storage capa...

Страница 13: ...Part Number 020004000 10 13 2 7 CEV40 FOOTPRINT Caution Cutting the countertop may decrease its strength Counter should be braced to support the dispenser countertop weight plus ice storage capacity a...

Страница 14: ...rs which are followed rapidly by loss of consciousness and suffocation If a CO2 gas leak is suspected particularly in a small area immediately ventilate the area before repairing the leak CO2 lines an...

Страница 15: ...installed and grounded in accordance with all local codes and ordinances Warning All wiring must conform to local state and national codes Dispenser Voltage Cycle Fuse Size Circuit Amps CEV 30 CEV 40...

Страница 16: ...pulling on cord To unplug grasp the plug not the cord Unplug from outlet when not in use and before servicing or cleaning Do not operate any appliance with a damaged cord or plug or after the applian...

Страница 17: ...ose is secure 2 Remove the plug from the water fill hole located on the carbonator pump deck Fill the water tank with clean water until water flows out of the tank overflow Use a funnel if necessary C...

Страница 18: ...nit the time delay will need to be observed before the compressor and fan motor will start INCOMING WATER SUPPLY REQUIREMENTS NOTE Manitowoc Beverage Equipment recommends that a water shutoff valve an...

Страница 19: ...or tank and must be routed to a drain Route carbonator tank purge tube A down front of unit and behind drain pan Be sure not to collapse or kink carbonator tank purge tube during routing from unit to...

Страница 20: ...en the discharge fitting on the carbonator and the dispensing valve 3 Open carbonator tank pressure relief valve Yellow arm should be in the upright position 4 Turn water supply on and fill the carbon...

Страница 21: ...020004000 10 13 2 15 PLUMBING DIAGRAMS NOTE A check valve must be installed in the water supply line 3 feet from the noncarbonated water connection PW Contact factory if not installed CEV 30e CEV 30i...

Страница 22: ...Installation Instructions Section 2 2 16 Part Number 020004000 10 13 CEV 40e CEV 40i 8Valve Diagram CEV 30j 4 5 6 Valve Diagram...

Страница 23: ...without the BIB installed as the pump could be damaged Set final secondary regulator pressure 70 75 psi 482 6 517 1 KPa depending on the line size and the distance of the run 3 Operate each dispensin...

Страница 24: ...enter the ADA Key Pad Box with the unit in front of the drain pan and secure into place 8 Apply corresponding drink labels to the ADA key pads NOTE Drinks correspond from left to right on the left sid...

Страница 25: ...all the screws that hold them in place 10 Restore power to the unit Clean Up Clean up all work areas Dispose of all packing material excess tubing and trash properly 1 2 3 4 5 6 7 8 9 10 1 2 3 4 4 Val...

Страница 26: ...and one inlet for CO2 If you have questions refer to the plumbing diagram on your equipment The outlet of the syrup supply either BIB pump or Figal tank connects to the appropriate syrup inlet fitting...

Страница 27: ...ops which in turn automatically starts the carbonator water pump When the water level inside the tank has been replenished carbonator water pump will stop CEVe The CEV 30e is a 5 or 6 valve unit and t...

Страница 28: ...and on to maintain a preset level of liquid in the tank The water level control may be electronic probes or a mechanical float SYRUP DELIVERY SYSTEM Your syrup location can vary depending on the volu...

Страница 29: ...ost Figal tanks have a self closing valve on the tank as well as the gas and syrup connectors This allows the operator of the system to change tanks without having to shut down the entire system With...

Страница 30: ...r LED only Green Carbonator LED Turned off on External Carb and Juice Units The green carbonator LED illuminates when carbonator switch is in the on position only applies to Internal Carb units The gr...

Страница 31: ...valves Nozzle Removal 7 Rinse nozzle and diffuser with warm clean water 8 Clean nozzles and diffusers with soapy water and a soft bristle brush 9 Clean the underside of the beverage valves with warm...

Страница 32: ...erage system at initial start up as well as regularly scheduled cleaning recommended at least twice a year The drain pan must be in place under soda valves to carry away detergent and sanitizing agent...

Страница 33: ...olution to remain in the system for 5 minutes 10 Connect Bucket 3 to system 11 Draw sanitizing solution through system until solution is dispensed 12 Repeat step 11 until all syrup circuits contain sa...

Страница 34: ...nk to the syrup line Draw clean rinse water through the valve until detergent is flushed from the system 7 Remove valve nozzle and diffuser as shown in Daily Cleaning instructions Using a plastic brus...

Страница 35: ...air replace HP regulator CO2 line pinched kinked or obstructed Check repair replace CO2 line One valve will not dispense anything Is there power to the valve Broken wire or loose connection Replace re...

Страница 36: ...pressure leading into pump inlet is 40 psi 275 79 KPa minimum with pump running Pump will not run but tank appears to be always full Common Lead Green shorted out to Red wire High Probe Verify Green...

Страница 37: ...s or minus 10 replace the Liquid Level Contorl board Pump motor starts and stops short cycles as soon as water level drops below Red High probe Black Low Lead wire is open or disconnected Verify conne...

Страница 38: ...Before Calling for Service Section 5 5 4 Part Number 020004000 10 13 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 39: ......

Страница 40: ...re Drive Sellersburg IN 47172 USA Ph 812 246 7000 Fax 812 246 7024 Visit us online at www manitowocfsg com 2013 Manitowoc Continuing product improvements may necessitate change of specifications witho...