Section 2
Installation Instructions
Part Number 020004000
10/13
2-13
CARBONATOR TANK PURGE TUBE ROUTING
1. During installation of unit the carbonator tank purge
tube (A) must be properly routed to a drain. Once
the splash panel has been removed from unit
remove twist tie (B) that holds carbonator tank purge
tube.
2. Purge tube is connected to the pressure relief valve
on carbonator tank and must be routed to a drain.
Route carbonator tank purge tube (A) down front of
unit and behind drain pan. Be sure not to collapse or
kink carbonator tank purge tube during routing from
unit to drain.
3. The carbonator tank purge tube (A) can be routed
down through the counter top that unit has been
installed on or out the rear of unit. Then install
carbonator tank purge tube to a drain. Follow all
local and national plumbing codes when routing
carbonator tank purge tube to the drain.
NOTE: If there is no permanent drain, route the
carbonator purge tube into the drainpan.