2021/8/19
www.sermatec-ess.com
27
Installation
Communication cable connection
STEP 1:
Remove the waterproof cover plate that comes with
the Hybrid Inverter
STEP 2:
Plug the wire connector of the waterproof cover plate
in the accessory into the corresponding interface of the
Hybrid Inverter.
STEP 3:
Fix firmly by screw.
STEP 4:
Screw up water-proof cylinder, connect the cable from
“RS485” interface to the interface of Power Meter,
connect the cable from “To battery” interface to BMS
interface in battery ( default length of cable is 3m)