8.1.1 Saving the configuration
After each change made to the con
fi
guration of the AsteRx SB Sx , the pop-up shown in
Figure 8-1 will appear. Clicking on
‘
Save
’
will cause the new con
fi
guration to be applied
the next time the receiver is powered.
Con
fi
gurations can also be saved as text
fi
les
and uploaded to other receivers. See Section 8.1.2 for more information on managing
con
fi
gurations.
Figure 8-1:
The
‘
save to Boot
’
pop-up
I
f you have consistently pressed
‘
Save
’
when the pop up appears on the screen, all settings
will be persistent and will be applied again when the device powered on.
You can also save the current con
fi
guration as the boot con
fi
guration on the
Admin/Configurations
window as shown in Figure 8-2. Select
Current
and
Boot
from the
drop-down lists as shown then click on
Ok
to apply the setting.
Figure 8-2:
Select
‘
Current
’
as Source and
‘