Operating the DVR
4–14
700-0048 R003
Smart-Link
voltage
indicator
The Smart-Link module also has a voltage indicator, which works differently than the
LOW
VOLTAGE
/
LOW
/
HIGH
TEMP
indicator on the DVR. For the Smart-Link, the green
POWER
ON
/
LOW
VOLTAGE
indicator will be illuminated when the DVR is powered up
and the operating voltage is above 10.5 VDC. When the voltage falls below 10.5 VDC,
the indicator will flash once every 2 seconds. If the voltage falls below 7.5 VDC, the
indicator will flash quickly (about twice per second) and the DVR will turn off the power
to any attached peripherals (such as a GPS module or the driver’s indicator panel).
The
LOW
/
HIGH
TEMP
indicator also illuminates according to the temperature inside the
DVR. These settings are described in “4.8. Advanced Smart-Temp”.
4.8. Advanced Smart-Temp
The EX8 Plus System incorporates several advanced features not found in any other
system on the market such as the Advanced Smart-Temp™. Advanced Smart-Temp and
the built-in heater ensure safe operation of the DVR over a wide temperature range.
Advanced Smart-Temp monitors the temperature inside the DVR to ensure the hard
drive operates in a safe environment. In many areas, the temperature drops well below
40°F (4°C) and quite often below 32°F (0°C). Most computer hard drives are designed to
work from about 40°F (4°C) to about 120°F (49°C).
Table 4-5
LOW VOLTAGE/LOW/HIGH TEMP indicator
Voltage level to DVR
LOW
VOLTAGE
/
LOW
/
HIGH
TEMP
indicator will …
Status of the DVR
Below 10.5 VDC
Illuminate
The DVR will stop recording and begin to shut
down as the voltage is too low to operate the
camera properly.
Rises to 11 VDC
Turn off
The DVR operation will return to normal.
Table 4-6
Advanced Smart-Temp features
Temperature inside
DVR
Advanced Smart-Temp…
LOW
/
HIGH
TEMP
Indicator
status
Below 40°F (5°C)
Turns on the internal heater and pulses the
system fan to circulate the warm air.
Flashes to indicate that the
temperature is too low.
Below 5°F (–15°C)
Will not power the DVR at all, although the
hard drive can still be removed from the DVR.
Flashes to indicate that the
temperature is too low.
Above 113°F (45°C)
Turns on the system fan.
Flashes to indicate that the
temperature is too high.
Above 140°F (60°C)
Shuts down the DVR to protect the hard drive
from damage. The system fan will continue to
operate.
Flashes to indicate that the
temperature is too high.
Содержание Explorer EX8Plus Mobile
Страница 2: ......
Страница 4: ......
Страница 10: ...vi...
Страница 12: ...viii...
Страница 14: ...x...
Страница 23: ...CHAPTER 2 Installation This chapter provides information and procedures for installing the EX8 Plus System...
Страница 39: ...CHAPTER 3 Configuring the DVR This chapter provides information and procedures for configuring the DVR...
Страница 75: ...CHAPTER 4 Operating the DVR This chapter provides information and procedures for operating the DVR...
Страница 92: ...5 4...
Страница 96: ...6 4...
Страница 103: ......