![Sentiotec just sauna combi Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/sentiotec/just-sauna-combi/just-sauna-combi_instructions-for-installation-and-use-manual_1244682025.webp)
WORLD OF WELLNESS
En
Installation instructions, only for experts
p. 25/50
5.12. Remote start
The remote start function is deactivated ex-works. When the remote
start function is activated when starting up the unit for the i rst time,
the sauna control unit may only be used for operating and regulating
a sauna heater which has been certii ed as satisfying the combustion
test described in paragraph 19.101 of EN 60335-2-53. Alternatively, the
corresponding safety shut-off device may be installed in, or above, the
sauna heater. Activation must be carried out by an electrician (see
8.4.
Activating/deactivating the remote start function
on page
30
).
!
The remote start device is connected using terminals “
S
”, “
B
” and “
C
”. “
S
” stands for
sauna mode and “
C
” for evaporator mode. “
B
” is a +24 V DC output. The preferred
operating mode must be activated using a switch or actuator on the terminal.
5.13. Status output
Any electrical device can be connected to the status output terminal which is
suitable for 24 V DC voltage and draws a current no greater than 200 mA.
Make sure the polarity is correct when connecting a device. When LEDs are
used, a suitable series resistor must be used.
5.14. Finishing installation
1. Connect the earth conductor for the power supply cable and all devices to
the earth rail
h
.
2. Place the cover of the housing on the upper edge of the junction box.
3. Push the clip locks inwards lightly, and turn the cover of the housing down-
wards until it engages audibly.