Installation instructions, only for experts
p. 16/50
To install the operating unit, perform the following steps:
1. Prepare an installation cut-out (213 x 82 mm) in the wall of the sauna.
2. Place the installation frame
A
into the installation cut-out.
3.
Afix the installation frame by bending the ixing plates
D
outwards using
a screwdriver.
4. Lay the RJ-12 cable in the wall of the sauna room, leading it from the power
unit installation location to the installation cut-out for the operating unit.
5. Connect the plug of the RJ-12 cable to the connection socket on the rear
of the operating unit.
6. Place the operating unit
C
into the installation frame
A
.
4.3. Installing the heater sensor F1 with excess temperature fuse
Observe the following points when installing the heater sensor:
●
The heater sensor must be installed on the rear of the heater, above the mid-
dle of the sauna heater. An interval of approx. 15 cm to the roof of the sauna
room must be maintained.
● The heater sensor must be attached in a way that it is not affected by a low
of air.
To install the heater sensor, perform the following steps (see
Fig. 4
):
1. Lay the two 2-pin heater sensor wires in the wall of the sauna room, leading
them to the heater sensor installation location and afix the heater sensor
wires using wire clips.
2. Pull the two half-shells
1
of the heater sensor apart.
3. Connect the four connectors for the heater sensor wire
5
in accordance
with the
Fig. 4
.
4. Place the connection panel
2
crossways (as shown in
Fig. 4
) in the heater
sensor half-shells.