![Sentiotec just sauna combi Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/sentiotec/just-sauna-combi/just-sauna-combi_instructions-for-installation-and-use-manual_1244682010.webp)
WORLD OF WELLNESS
Instructions for installation and use
p. 10/50
●
Remote start function
The remote start function is deactivated ex-works. When the remote start func-
tion is activated when starting up the unit for the irst time, the sauna control
unit may only be used for operating and controlling a sauna heater which
has been certiied as satisfying the combustion test described in paragraph
19.101 of EN 60335-2-53. Alternatively, a suitable safety shut-off device can
be installed in or above the heater. Activation of the remote start function
must be carried out by an electrician (see
8.4. Activating/deactivating the
remote start function
on page
30
).
●
Status output
●
Automatic heating period limiter
If the operating unit has been running continuously for 6 hours, the sauna
control unit switches off all the consumers for safety reasons. The operating
unit goes into standby mode.
●
Post-drying programme
Once combi-mode has inished, the post-drying programme starts automati
-
cally to prevent mould or rot from forming in the sauna room. This involves
heating the sauna room to 80 °C with the fan running for 30 minutes.
●
Excess temperature fuse
The excess temperature fuse is installed in the housing for the heater sen-
sor. Should the sauna heater continue heating after reaching the preferred
temperature due to a defect, the excess temperature fuse switches the sauna
heater off at a temperature of approx. 139 °C.
3.4. Sauna operating modes
The sauna control unit just sauna combi provides two operating modes, sauna
mode and combi mode.