![Sentiotec just sauna combi Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/sentiotec/just-sauna-combi/just-sauna-combi_instructions-for-installation-and-use-manual_1244682021.webp)
WORLD OF WELLNESS
En
Installation instructions, only for experts
p. 21/50
Observe the following points when connecting the power to the sauna control unit:
● Installation may only be performed by a qualii ed electrician or similarly quali-
i ed person.
Please observe that in the event of a guarantee claim, a copy of the bill
from the electrician performing the work must be presented.
●
Work on the sauna control unit may only be performed when the power has
been disconnected.
● The electrical supply must be a i xed connection.
●
A three-phase shut-off device with a 3 mm contact opening must be provided
in the installation. This is provided by the fuse.
●
Observe the connection diagram (
Fig. 5
) on page
28
.
5.1. Connecting the power supply cable, heater and evaporator
1. Guide the power supply, heater and evaporator cable through the cable
bushings
a
,
9
,
8
into the connection area for 230 V/400 V
g
.
2. Connect the power supply cables to the terminal strip
d
in accordance
with the connection diagram. Observe the operating instructions for the
respective devices.
3. If the evaporator does not feature an automatic low-water shut-off function,
then perform the following step as well:
●
Use the wire jumper enclose to connect terminal “
V1
” to terminal “
Wm
”.
5.2. Connecting the operating unit
1. Guide the connection cable for the operating unit through the cable bush-
ing
5
into the low-voltage connection area
1
.
2. Connect the plug of the RJ-12 cable to the connection socket
3
.