5.7. Connecting heater sensor F1
1. Guide the wires for the heater sensor through the cable bushing
6
into the
low-voltage connection area
1
.
2. Connect the red wires for the heater sensor to the terminals labelled “
STB
”
in terminal strip
2
.
3. Connect the white wires for the heater sensor to the terminals labelled “
F1
”
in terminal strip
2
.
5.8. Installing bench sensor F2 (optional)
1. Guide the wires for the bench sensor through the cable bushing
5
into the
low-voltage connection area
1
.
2. Connect the wires for the bench sensor to the terminals labelled “
F2
” in
terminal strip
2
.
5.9. Installing humidity temperature sensor FTS2 (optional)
1. Guide the wires for the sensor through the cable bushing
6
into the low-
voltage connection area
1
.
2. Connect the wires for the temperature sensor to the terminals labelled “
F2
”
in terminal strip
2
.
a. Connect the black wire to the right terminal.
b. Connect the brown wire to the left terminal.
3. Connect the wires for the humidity sensor to the terminals labelled “
+ S -
”
in terminal strip
2
.
c. Connect the green wire to terminal “
+
”.
d. Connect the orange wire to terminal “
S
”.
e. Connect the red wire to terminal “
-
”.