Installing the FP400 processor
Page 42
FP400 Product Guide
Free-standing or fence post mounting the enclosure
To post mount the processor, install it inside a weatherproof field distribution box.
•
Install the processor near eye-level on the secure side of the perimeter.
•
Install an approved earth ground at the processor location.
•
Mounting the enclosure away from the protected fence on the secure side of the perimeter can
help prevent tampering.
•
If razor ribbon is installed along the bottom of the fence, mount the processor on the secure
side of the perimeter, away from the fence and razor ribbon.
Figure 42 FP400 indoor wall-mount installation example
Figure 43 FP400 outdoor post-mount installation example
wall-mounted
splice enclosure
6 relay 2 auxiliary/self-test
power
ground
FP400
TX/RX fiber connections (X8)
lead-in cable to
service loop
inputs
outputs
supply
processor
sensor zones
enclosure
processor
outdoor splice enclosures for
FP400 processor
lead-in cable
service loop
service loops
service loop
processor ground connection
sensor cable zone 4
zone 1 & 4 start modules
to zone 1 end module
zone 2 start module
to zone 4 end module
zone 3 end module
sensor cable zone 1
Customer-supplied
weatherproof outdoor enclosure
Z1
Z4
Содержание FiberPatrol FP400