Installation on fences
FiberPatrol FP1150 Product Guide
Page 53
8.
Attach the sensor cable at the junction of two fence wires app. 25 cm before the third post
(point j).
9.
Attach the sensor cable at 50 cm intervals on the second fence panel (points k, l).
10. Proceed along the perimeter, attaching the cable to the fence one panel at a time.
Attaching the sensor cable at protected gates
Before attaching the sensor cable to a gate, ensure that there is a sufficient amount of sensor
cable laid out to:
•
cover the gate
•
form the sensitivity loops
•
make a 10 m service loop on hinged side(s) of gate
•
make 13 m isolation loops (optional)
1.
Refer to the site plan and lay out a sufficient amount of sensor cable in a figure 8 pattern.
2.
Loosely attach the sensor cable to the post on which the gate is hinged. Attach the sensor
cable to the gate at ¼ the fence height, 30 cm away from the outside edge, and ¾ of the fence
height.
3.
Hold the conduit against the fence post and on the conduit, mark the positions of any
hardware on the fence post that will require notches in the conduit.
4.
Make any required notches in the conduit.
5.
Place the notched half of the conduit under the cable against the fence post and hold it in
place.
6.
Press-fit the sensor cable into the split loom so the split loom extends 7.5 cm (3 in.) beyond
the top and bottom of the split conduit.
7.
Fit the other half of the conduit over the split loom and cable and secure the conduit to the
fence post with the supplied gear clamps. Ensure the split loom covers the sensor cable, and
protects it from chafing against the top and bottom edges of the conduit.
8.
Form a sensitivity loop and attach the sensor cable to the fence panel leading up to the gate.
9.
Form a sensitivity loop and attach the sensor cable to the fence panel leading away from the
gate.
Figure 61 Cable installation on gates
service loop
attach the cable securely on the gate panel
and the fence fabric leading up to the gate
do not attach the sensor cable in the sections
that must rotate when the gate is in use
cut notches in the split tube if necessary to accommodate
post fittings so it sits flush against the fence post
Содержание FiberPatrol FP1150 Series
Страница 72: ...Troubleshooting procedures Page 72 FiberPatrol FP1150 Product Guide ...
Страница 124: ...Page 124 FiberPatrol FP1150 Product Guide ...
Страница 134: ...Page 134 FiberPatrol FP1150 Product Guide ...