FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Mounting and
operating instructions
66
8.5.1
Set
switching output Q
1
Command (Byte 3):
decimal 49; hexadecimal 0x31
Parameter format:
Parameter:
Switching point 1
12 bit data item: data 1
Configuration
D0: 0 = N.O., 1 = N.C.
D1: 1 = pulse stretching, 0 = OFF
7 bit data byte
Switching point 2
12 bit data item: data 1
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Switching output Q
1
is defined (switch points 1+2, configuration)
Example telegram
(in this example the sensor has the address 1, switching output is defined as N.O. without pulse stretching, switch
point 1 = 2049, switch point 2 = 0)
Master telegram
Sensor’s reply telegram
Designation
Decimal
Hex.:
Designation
Decimal
Hex.:
1. Byte
Address
129
81
1. Byte
Address
129
81
2. Byte
Length
9
09
2. Byte
Length
4
04
3. Byte
Command
49
31
3. Byte
Reply
89
59
4. Byte
Switching point 1
33
21
4. Byte
Check sum
92
5C
5. Byte
0
00
6. Byte
Configuration
0
00
7. Byte
Switching point 2
0
0
8. Byte
0
00
9. Byte
Check sum
24
18
8.5.2
Set switching output Q2
Command (Byte 3):
decimal 50; hexadecimal 0x32
Parameter format
Parameter:
Switching point 1
12 bit data item: data 1
Configuration
D0: 0 = N.O., 1 = N.C.
D1: 1 = pulse stretching, 0 = OFF
7 bit data byte
Switching point 2
12 bit data item: data 1
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Switching output Q
2
is defined (switch points 1+2, configuration).