FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Mounting and
operating instructions
48
Connection Colour Use
Remark
1 (WH)
White
RS485 Data+ (Y/A)
S1 version only
2 (BN)
Brown
+ U
B
3 (GN)
Green
As signal output Q
1
or input with optional input function (see
chapter 7 „Use and configuration”)
Q
1
4 (YE)
Yellow
As signal output Q
2
or switching function “good target” (detec
-
table object in measuring range)
Q
2
or Good Target
5 (GY)
Grey
RS485 Data- (Z/B)
S1 version only
6 (PK)
Pink
Q
A
+ analogue measurement
7 (BU)
Blue
- U
B
8 (RD)
Red
Q
A
- analogue mass
Once power supply has been connected, the FT 50 RLA is ready for operation after a short stand-by delay
(< 300 ms).
INFORMATION
For maximum precision, please allow for a heating period (approx. 15 minutes).
7
Use and configuration
The sensor has different operating modes and functions.
Sensor configuration can be carried out via the control panel using the
SET
and
keys.
CAUTION
Push buttons only with finger! Do not use sharp objects!
With FT 50 RLA ... S1 (with RS485 interface) it is also possible to adjust the sensor functions via the serial interface.