FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Mounting and
operating instructions
49
7.1
Displays and configuration elements
The LEDs (illustr. 11) indicate the selected menus and configurations.
Keys and their functions:
The FT 50 RLA is configured using the
SET
and
keys.
General operating functions
Keys
In operating mode
In configuration mode
Entire control
panel
SET
Activate set-up mode:
Simultaneously pressing these keys
(> 3 s)
activates the set-up mode.
After this period, the
power supply
indicator BA
flashes
set FT 50 RLA, see illustr. 11.
The LEDs show the status of function
no.1.
When
all the LEDs
start immediately
flashing
Unlock
FT 50 RLA, see
„Unlocking keys” (below).
Quit set-up mode:
First press the
key and then also the
SET
key.
All settings are then stored.
Once the
SET
key is released, the sensor is in
RUN mode.
The operating indicator BA lights up permanently
again.
INFORMATION
Should the power supply fail during the
setting procedure, all settings are lost.
Illustr. 11
15500272
Q
I
C
1
2
Q
OK
FA
Exit
Conf
BA
ZA
SET
LED Colour In operating mode
In configuration mode
BA
Green
Operating indicator (LED lights up,
when sensor is ready for use)
LED flashes, when set-up mode
is active.
ZA
Red
Staus indicator:
Lights up when function is active.
Off, when function is not active.
During teach-in: confirmation
signal
Q
1
Yellow
Lights up when Q
1
input/output
is active
Table of functions on chapter 7.2.2
onwards explains the significance
of the Q
1
, Q
2
, I, OK, C and FA
LEDs in set-up mode.
Q
2
Yellow
Lights up when Q
2
output is active
I
Green
Lights up when Q
1
trigger input or
Q
1
enable input function is active
OK
Green
Good Target (lights up when object
is detected and in measuring
range)
C
Green
Lights up when sensor is program-
med as master or slave
FA
Green
Lights up when Q
1
autom. centre
or Q
1
autom. zero function is
active