FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Mounting and
operating instructions
50
General operating functions
Keys
In operating mode
In configuration mode
SET
SET
No function
A brief pressing of the
SET
key changes the
status of respective function or activates storage
and confirmation of the set values.
The function status is indicated by the status
indicator
ZA
(LED ON = active, LED OFF = not active).
A
ctivate factory setting during
Power ON:
Keep
SET
key pressed
(approx. 10 s)
,
until the LEDs stop flashing and light up
permanently. The operating indicator BA
lights up green.
Once the
SET
key is
released
, the
sensor is reset. The
FT 50 RLA
is now in
its
initial state.
Continue
No function
Press
the
key to select the next function in
the function table.
The function number is indicated by a
clear
LED
pattern.
The first function follows the last available
function.
Unlock keys
during
Power ON
:
Keep
key pressed
(approx. 10 s)
,
until the LEDs stop flashing and light up
permanently. The
status indicator ZA
lights up
red
.
The control panel is unlocked once the
key is released.
INFORMATION
A time lock prevents short unintentional pressure on the keys from activating configuration
mode.
7.2
Setting functions with the control panel
7.2.1
Quick user guide (068-13884) see fold-out page