Sensor head substitution
If necessary, the sensor head can be substituted. First of all, the user must request to
Sensitron and Sensitron will give a proper kit and instructions.
ATTENTION!
It’s strictly forbidden open and close the equipment when it’s installed in
hazardous area and it’s powered
-on. This operation can be conducted in
safe zone and without power source. After 10 minutes from power source
interruption, the equipment can be opened.
It’s strictly recommended t
he use of personal protective equipment
during operations inside the enclosure.
In case of tapered thread, use a thread-lock glue (Loctite 243 for example) on 2-3 threads.
7.4
Cleaning
The detectors must be kept clean of dust deposits. Cleaning must be performed with
damp cloths or with cloths that do not accumulate electrostatic charges. It’s strictly
forbidden the dust cleaning using compressed.
Gas detectors must be cleaned in order to avoid any risk of infection
ATTENTION!
The
detectors must be kept clean of dust deposits. It’s strictly forbidden the dust
cleaning using compressed. Cleaning must be performed with damp cloths or with
cloths that do not accumulate electrostatic charges, in particular, when the
equipment has a varnished aluminum enclosure.