background image

QUICK GUIDE

GROUND BALANCE

Rotate the 
sensitivity knob 

to maximum 
and the ground 

balance knob to 
the mid-level.

If the detector emits false signals due to interference, 
reduce the sensitivity until the signals go away and 

start searching.

Sensitivity is also the depth setting for the device. 
Therefore, it is recommended that you do not lower it 

too much suddenly but gradually decrease it to 
determine the level where you are not getting any 

interference and continue searching.

Holding the search coil 5cm. 
above the ground, sweep it 

right and left.

Turn on the device 
by setting the 

search mode knob 
to ALL METAL.

Approximately 20 

seconds later, the LEDs 

on the handle will go off 

and you will hear a tone 

indicating that the device 

is ready to use.

When the device detects a metal, it will produce an audible tone. For pinpointing the exact location of the target, move the search coil 
over the target with short and faster/slower sweeps.

The most important thing to pay attention here is that as the ground balance goes into the right area, the device will start losing depth 
for some non-ferrous metals except for gold. When the ground balance setting reaches the maximum point the device will detect iron 
and gold but it will not detect some non-ferrous metals.

3) RIGHT AREA: Is used to eliminate high mineralized rocks and soils. If you are on a highly mineralized ground and the device is still getting 
ground noise with the ground balance set at mid-level, turn the ground balance knob to the right in very small increments to eliminate the 
noise.

Golden Sense ground balance setting consists of 3 different levels:

1) MID-LEVEL: Offers the most ideal and stable detection capability on different types of 
grounds without sacrificing depth.

2) LEFT AREA: Recommended for more precise detections and for experienced users. 
The device may generate false signals in changing ground conditions, even over holes 

dug for testing. Therefore, if you set the ground balance in this area, you have to take 
this factor into consideration.

After the ground balance and 
sensitivity settings are 
adjusted, you can start 
searching by lifting the search 
coil 5cm. above the ground and 
sweeping it right and left, 
keeping it parallel to the 
ground.

To avoid missing smaller and 
deeper targets, sweep the 
search coil both from right to 
left and left to right over each 
area you are scanning, slightly 
overlapping the sweeps as you 
move forward.

GROUND BALANCE

2) LEFT AREA

3) RIGHT AREA

1) RECOMMENDED SETTING

MID-LEVEL

SENSITIVITY

SENSITIVITY

TURNING ON THE DEVICE

SENSITIVITY SETTING

1

2

SEARCHING AND METAL DETECTION

3