It is not of importance, whether the sensor cable is installed with ascending or descending imprints,
since a logical order may be programmed later.
It is recommended, that imprints at the ends of sensor cable sections be noted on a plan or drawing.
Imprints at zone borders and other important points should also be noted. This information is needed for
the system configuration.
Sensors are marked by two imprints on opposing sides of the sensor cable to facilitate quick location.
Pre- and post-runs:
The manufacturing process requires the sensor cable to be manufactured with pre- and post-runs.
These can be up to 24m long and do not contain sensors. Pre- and post-runs are
not
part of the
length(s) shown on the delivery notes.
When installing the cable, proceed as follows:
1. Use the delivery note or spool label to determine the imprint of the first sensor. Sensors are
alwayslocatedunder the sensor imprint.
2. Cut and seal the sensor cable at least 50 cm before the first sensor. The same applies for the
end of the sensor cable.