3. Sensor cable ends should extend at least 30 cm over connection points in a SCU 800 or
connection boxes
Important: ♦
Open cable ends must be sealed immediately.
♦ Cut the cable at least 50 cm from sensor imprints.
♦ Use suitable cutters to cut the sensor cable.
4.2
CONNECTION BOXES
Sensor cables can also be connected to a SCU 800 with CC15 connection cable. The change from a
sensor cable to the connection cable may occur in a connection box (CBO).
Note:
To ensure ingress protection (IP), use the correct mounting holes.
Important:
Close all unused openings with plugs.
Use the supplied O-rings on glands and plugs.
Dimensions:
APPENDIX: DIMENSIONS: CBO 5-SEC AND CBO 5-ESD-T
Page 18/44
LISTEC GmbH
60T023-04 / 30.04.2014