background image

SKP 300 G3

  | 31

Manufacturer Declarations

Manufacturer Declarations

Warranty

Sennheiser electronic GmbH & Co. KG gives a warranty
of 24 months on this product.

For the current warranty conditions, please visit our
web site at www.sennheiser.com or contact your
Sennheiser partner.

In compliance with the following requirements 

RoHS Directive (2002/95/EC)

WEEE Directive (2002/96/EC)

Battery Directive (2006/66/EC)

CE Declaration of Conformity

R&TTE Directive (1999/5/EC)

The declaration is available at www.sennheiser.com.

Before putting the product into operation, please
observe the respective country-specific regulations.

Statements regarding FCC and Industry Canada

This device complies with Part 15 of the FCC Rules and
with RSS-123 of Industry Canada. Operation is subject
to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must
accept any interference received, including interference
that may cause undesired operation.

This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interfer-
ence in a residential installation. This equipment gener-
ates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio commu-
nications. However, there is no guarantee that interfer-
ence will not occur in a particular installation. If this
equipment does cause harmful interference to radio or
television reception, which can be determined by
turning the equipment off and on, the user is encour-
aged to try to correct the interference by one or more of
the following measures:

Please dispose of the plug-on transmitter at the
end of its operational lifetime by taking it to
your local collection point or recycling center for
such equipment.

The supplied batteries or rechargeable batteries
can be recycled. Please dispose of them as
special waste or return them to your specialist
dealer. In order to protect the environment, only
dispose of exhausted batteries.

0682

Содержание SKP 300 evolution wireless G3

Страница 1: ...SKP 300 Instruction manual...

Страница 2: ...activating the lock mode temporarily 11 Muting the audio signal or deactivating the RF signal 12 Selecting a standard display 13 Using the operating menu 14 The buttons 14 Overview of the operating me...

Страница 3: ...equired if the device has been damaged in any way liquid has been spilled objects have fallen inside the product has been exposed to rain or moisture does not operate properly or has been dropped WARN...

Страница 4: ...in multi channel operation 48 V phantom powering Areas of application The plug on transmitter can be combined with the EM 300 G3 rack mount receiver The EM 300 G3 rack mount receiver is available in...

Страница 5: ...frequency presets please refer to the supplied frequency information sheet Updated versions of the frequency information sheet can be downloaded from the SKP 300 G3 product page on our website at www...

Страница 6: ...on transmitter 2 AA size batteries 1 5 V 1 instruction manual 1 frequency information sheet 1 RF power information sheet A list of accessories can be found on the SKP 300 G3 product page at www sennhe...

Страница 7: ...ale balanced 2 Mechanical locking ring of XLR 3 socket 3 Infra red interface 4 Display panel backlit in orange 5 UP button 6 DOWN button 7 Operation and battery status indicator red LED lit ON flashin...

Страница 8: ...lay Meaning 1 Audio level AF Modulation of the plug on trans mitter with peak hold function 2 Frequency Current transmission frequency 3 Name User selectable name 4 Transmission icon RF signal is bein...

Страница 9: ...n of the embossed arrow and open the cover A Insert the two batteries or the accupack as shown below Please observe correct polarity when inserting the batteries accupack Close the battery compartment...

Страница 10: ...microphone s XLR 3M socket onto the XLR 3F socket 1 of the transmitter Make sure that the latch B locks into place Tighten the locking ring 2 in the direction of the arrow The transmitter uses the mi...

Страница 11: ...mitter on online operation To switch the plug on transmitter on and to deactivate the RF signal on switch on offline operation It is vital to observe the notes on frequency selec tion on page 23 Press...

Страница 12: ...nel Press the UP DOWN button RF Mute Off appears on the display panel Press the SET button The transmission icon 4 is displayed again Keep the ON OFF button 8 pressed until OFF appears on the display...

Страница 13: ...e page 21 From the Mute Mode menu item select the desired setting see page 21 Exit the operating menu Slide the MUTE switch 9 to the left to the position MUTE The plug on transmitter reacts as indicat...

Страница 14: ...TE 7 is displayed transmission icon 4 is not displayed You can also deactivate the RF signal on switch on For more information refer to the chapter Switching the plug on transmitter on off on page 10...

Страница 15: ...es deactivates the RF signal Press the SET button Changes from the current standard display to the operating menu Calls up a menu item Enters a submenu Stores the settings and returns to the operating...

Страница 16: ...ute Mode Sets the mode for the MUTE switch 9 21 RF Power Adjusts the transmission power 21 PhantomPower 48V Activates deactivates the phantom powering 21 Pilot Tone Activates deactivates the pilot ton...

Страница 17: ...adjust the input sensitivity Press the SET button to store the setting Press the ON OFF button to cancel the entry The current standard display appears on the display panel Press the SET button repeat...

Страница 18: ...even if the plug on trans mitter is muted e g allowing you to check the adjusted sensitivity before live operation Input sensitivity adjusted Effect display too high Close talking distances speakers...

Страница 19: ...requency bank System bank frequencies are factory preset U1 to U6 up to 24 per frequency bank User bank frequencies are freely selectable When setting up multi channel systems please observe the follo...

Страница 20: ...ent channel of the frequency bank U1 to U6 2 or select a frequency bank U1 to U6 and a channel and assign this channel a transmission frequency Press the UP DOWN to select the desired setting When you...

Страница 21: ...ress the SET button Your settings are stored You are back to the operating menu Press the UP DOWN button until the Tune menu item appears Keep the SET button pressed until the frequency bank selection...

Страница 22: ...ion no audio signal is transmitted RF On Off When the switch is in the MUTE posi tion the RF signal is deactivated Disabled The muting function is deactivated It is vital to observe the notes on the e...

Страница 23: ...steps Resetting the settings made in the operating menu Reset When resetting the settings made in the operating menu only the selected settings for the pilot tone and for the frequency banks U1 to U6...

Страница 24: ...with the icon Alternatively you can set the channel on the plug on transmitter manually Make sure that you set the plug on transmitter to the same frequency bank and the same channel as the receiver...

Страница 25: ...eivers ew 300 G3 plug on transmitters can form transmission links that can be used in multi channel systems For information on automatic synchronization of plug on transmitters with receivers multi ch...

Страница 26: ...cloth to clean the plug on transmitter from time to time CAUTION Liquids can damage the electronics of the plug on transmitter Liquids entering the housing of the device can cause a short circuit and...

Страница 27: ...er observe a minimum distance of 5 m between plug on trans mitter and receiving antennas The plug on transmitter uses the microphone body as an antenna therefore microphones with a metal casing should...

Страница 28: ...plug on trans mitter to the same channel as the receiver Synchronize the plug on transmitter with the receiver see page 23 Transmission range is exceeded Reduce the distance between plug on transmitt...

Страница 29: ...vail able no SKP 300 display on the receiver Plug on trans mitter and receiver do not have software version 1 7 or higher Update the software of plug on trans mitter and receiver The current software...

Страница 30: ...15 ppm RF output power at 50 switchable typ 10 mW Low typ 30 mW Standard Pilot tone squelch can be switched off Compander system Sennheiser HDX AF frequency response 80 to 18 000 Hz Signal to noise ra...

Страница 31: ...assignment of the XLR 3 socket Europe EMC EN 301489 1 9 Radio EN 300422 1 2 Safety EN 60065 EN 62311 SAR Canada Industry Canada RSS 123 IC 2099A G3SKP limited to 698 MHz USA FCC Part 74 FCC ID DMOG3SK...

Страница 32: ...quipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmfu...

Страница 33: ...an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV tech nician for help This class B digital device complies with the Canadian...

Страница 34: ...Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Printed in Germany Publ 12 11 544494 A01...

Отзывы: