Technical Manual
Absolute Single/Multiturn Encoders
Profibus
R.000.000
14-13 of 22
B
B
u
u
s
s
t
t
e
e
r
r
m
m
i
i
n
n
a
a
t
t
i
i
o
o
n
n
The
bus
termination
is
set
via
hardware
using
both
DIP
switches
on
the
bus
cover
on
the
rear
of
the
encoder.
When
the
switch
is
set
to
‘ON
‐
>
the
termination
is
active
If
the
device
represents
the
final
station
on
the
bus,
then
the
looped
‐
through
Profibus
must
be
actively
terminated
at
both
ends
with
a
bus
termination
resistor
between
A
and
B
.
At
closed
housings
it
is
necessary
to
order
with
termination
adjusted
the
right
way,
otherwise
it
is
mandatory
to
adapt
an
external
resistor.
14
4
Installation
notes
when
using
housings
with
cable
glands:
1
Installation notes when using housings with cable glands:
As
bus
or
connection
cable,
use
only
approved
Profibus
cable
with
suitable
shielding.
•
Place
the
cable
shield
on
the
cable
gland