Technical Manual
Absolute Single/Multiturn Encoders
Profibus
R.000.000
16-15 of 22
1
1
6
Scaling
6 Scaling
With
Standard
Scaling,
scaling
will
be
done
as
follows:
o
With
MUR
and
TMR
o
One
revolution
is
equivalent
exactly
to
MUR
=
TMR
values
Position
scaled
=
((Position
unscaled
/
Singleturn
‐
resolution)
*
MUR)
%
TMR
With
Alternative
Scaling,
scaling
will
be
done
as
follows:
o
With
NDR
and
TMR
o
NDR
revolutions
are
equivalent
exactly
to
the
TMR
values
Position
scaled
=
((Position
unscaled
/
(NDR
*
Singleturn
‐
resolution))
*
TMR)
%
TMR
1. Code
sequence
CW
Possible
settings:
Increasing
clockwise
(0)
(CW)
Increasing
counter
‐
clockwise
(1)
(CCW)
2. Class
2
functionality
on
Class
2
must
be
turned
on
when
scaling
is
active.