3.3.16
Configuring Genlock
SDI Output modules
with the “Reference Source” configured as External must manually
define the Genlock Format for the card to lock to the Genlock signal. SDI over IP (2110)
modules require the “Reference Format” to always be configured to properly output
video. In Multichannel decode applications, the same Genlock reference is used for all
SDI outputs.
3.3.16.1
Genlock SDI Output Module
SDI Output Module Genlock settings can be activated in the Admin panel under the
ASI/SDI module.
3.3.16.2
Genlock 2110 Output Module
SDI over IP (2110) Output Module Genlock settings can be activated in the Admin panel
under the Video/IP module.