74
ProBee-ZE20S Series User Guide Rev.0.1
Execute ATS53?<CR>
ATS53=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 8
Range
0 – 16711680
9.5.4 S54
Description
Get/Set the standby timeout in seconds. When an end-device wakes up and polls with
the parent node, the node will wait for another data from the ZigBee network or from
the serial port for S54 before it goes to sleep mode again. If any serial or RF data is
sent or received, the timer will reset and wait for next again.
Execute ATS54?<CR>
ATS54=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 5
Range
0 – 10000
9.5.5 S55
Description
Get/Set the rejoin timeout. If it is enabled, an end-device tries to rejoin the current
network when contact with the network has been lost for setting value in seconds. The
most common usage case is when an end device can no longer communicate with its
parent and wishes to find a new one.
Execute ATS55?<CR>
ATS55=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 10
Range
0 – 10000
9.5.6 S56
Description
Get/Set the end device poll period in seconds. Adaptive polling may allow the end
device to poll more rapidly for a short time when receiving RF data.
Execute ATS56?<CR>
ATS56=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 5
Range
0 - 10000
Содержание ProBee-ZE20S Series
Страница 76: ...76 ProBee ZE20S Series User Guide Rev 0 1 10 Pin Assignments Figure 10 1 Pin Assignments...
Страница 78: ...78 ProBee ZE20S Series User Guide Rev 0 1 11 Mechanical Drawings Figure 11 1 ZE20SDU Mechanical Drawings...
Страница 79: ...79 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 2 ZE20SDC Mechanical Drawings...
Страница 80: ...80 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 3 ZE20SDS Mechanical Drawings...
Страница 81: ...81 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 4 ZE20SSU Mechanical Drawings...
Страница 82: ...82 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 5 ZE20SSC Mechanical Drawings...