32
ProBee-ZE20S Series User Guide Rev.0.1
ATM<CR>
Set multicast data mode to preconfigured destination group ID without reset.
ATM<value><CR>
Set multicast data mode and <value> can be 16-bit group ID.
AT+TRANSMITMODE=2<CR>
Set the transmit mode to multicast mode. The device should be reset to apply the mode.
ATS36=n, where n is the radius.
ATS37=n, where n is the number of hops through nonmembers.
Set data relay and forwarding options. Please refer to the
9 S-Registers
for more details.
Example)
AT+DESTGROUPID=0001<CR>
# Set the destination group ID
OK<CR>
#
Response
ATM<CR>
# Enter the multicast mode using destination group ID
OK<CR>
#
Response
Send multicast msg
# Put the multicast message
+++
#
Leave
data
mode
OK<CR>
#
Response
ATM0001<CR>
# Enter the multicast mode using 16-bit group ID
OK<CR>
#
Response
OK<CR>
#
Response
Send multicast msg
# Put the multicast message
+++
#
Leave
data
mode
OK<CR>
#
Response
AT+DESTGROUPID=0001<CR>
# Set the destination group ID
OK<CR>
#
Response
AT+TRANSMITMODE=2<CR>
# Set transmit mode to destination group ID
OK<CR>
#
Response
ATZ<CR> #
Apply
to
change
OK<CR>
#
Response
Send multicast msg
# Put the multicast message
+++
#
Leave
data
mode
Содержание ProBee-ZE20S Series
Страница 76: ...76 ProBee ZE20S Series User Guide Rev 0 1 10 Pin Assignments Figure 10 1 Pin Assignments...
Страница 78: ...78 ProBee ZE20S Series User Guide Rev 0 1 11 Mechanical Drawings Figure 11 1 ZE20SDU Mechanical Drawings...
Страница 79: ...79 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 2 ZE20SDC Mechanical Drawings...
Страница 80: ...80 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 3 ZE20SDS Mechanical Drawings...
Страница 81: ...81 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 4 ZE20SSU Mechanical Drawings...
Страница 82: ...82 ProBee ZE20S Series User Guide Rev 0 1 Figure 11 5 ZE20SSC Mechanical Drawings...