53
AT&Cn, AT&Wn, AT&Zn=x
Factory default response is ERROR.
This can be changed to OK by user configuration.
(Figure 4-8 )
ERROR [CR][LF]
or
OK [CR][LF]
ATFn [CR][LF]
None
If n=1 OK [CR][LF]
Else ERROR [CR][LF]
ATWn
None
If n=0 OK [CR][LF]
Else ERROR [CR][LF]
AT+DATE
Set the system data and time
e.g.
AT+DATE=2007.01.01-14:30:30
AT+NET
Set the IP address and the subnet mask.
e.g. AT+NET= 192.168.17.9/255.255.0.0
AT+GATEWAY
Set the default gateway
e.g. AT+GATEWAY=192.168.1.1
AT+DNS
Set the domain n ame server.
e.g. AT+DNS=168.126.63.1/168.126.63.2
If success,
OK [CR][LF]
If failure,
ERROR [CR][LF]
Table 4-3 AT commands Response Code
Verbose Code
(After “ATV1”command executed)
Non- Verbose Code(Numeric Code)
(After “ATV0” command executed)
Description
OK
0
Command executed
CONNECT
1
Modem connected to line
RING
2
A ring signal has been detected
NO CARRIER
3
Modem lost carrier signal
ERROR
4
Invalid command
Table 4-4 Default value of S-Registers
Index
Default Value
Index
Default Value
Index
Default Value
0 ~ 1
0
2
43
3
13
4
10
5
8
6
2
7
30
8
2
9
6
10
14
11
100
12
50
13 ~ 24
0
24
5
25
1
26 ~ 37
0
38
20
39 ~ 99
0