37
Figure 3-11 Locating server configuration
3.7.3. Locating server communication protocol
When the Pro Series sends its IP address information to the locating server, data format will be as
follows:
Description
Magic Cookie
Data(0)
Data(1)
…
Data(n)
Bytes
4
Variable
Variable
Variable
Value
F1-AA-AA-BC
Data(n) format
Description
Data ID
Length
Data
Bytes
1
1
Variable
Value
1~6
Variable
Variable
Data ID
ID
Description
Length
1
Device name
var
2
Model name
var
3
Serial number
var
4
MAC address
6
5
IP address
4
6
Local ports*
1 or 4 or 8
Note:
Local ports: Each 2 byte data represent current local port setting of the corresponding serial port. Local ports data
length of PS110 should be 2 bytes, while 8 bytes and 16 bytes for PS410 and PS810 respectively.
Configured
local TCP (or UDP) port numbers for each serial port are filled in the serial port number order base, (i.e. TCP or
UDP port number for serial port 1 first). If serial port is disabled, the local port number of that serial port is
regarded as 0.
Example of the PS110:
If port number = 7001 (1B59h), Local ports data = 1Bh, 59h
If serial port is disabled, Local port data = 00h, 00h
Example of the PS410:
Port1 = 7001 (1B59h), Port2 = 7010 (1B62h), Port3 = Disable, Port4 = 7004(1B5Ch)
Local ports data = 1Bh, 59h, 1Bh, 62h, 00h, 00h, 1Bh, 5Ch