62
Figure 4-14 Serial communication type and DIP switch configuration. (PS110/410)
For more information about pin out of serial port and wiring diagram, please refer to
Appendix 1
Connections
section.
NOTE
:
1.
Please turn off the power of the Pro Series device before changing the position of DIP
switch in case of PS110/410. Changing the position of DIP switch while the power is on
may cause damage to the device.
(If the DIP switches are set incorrectly the PS110/410 will display “Invalid” for the UART
type on the UI as shown on
Figure 4-15
, which will hinder communications to the serial
port.)
2.
In case of PS810, UART type can be changed by software through configuration only. So
PS810 does not have a DIP switch for changing UART type.
Figure 4-15 Invalid UART type settings displayed on the Serial port configuration main screen
Baud rate
The valid baud rate for the Pro Series is as follows:
75, 150, 200, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, and
230400
The factory default setting is 9600.
Data bits
Data bits can be between 7 bits and 8 bits. The factory default setting is 8 bits.
Parity
Parity can be
none, even
or
odd
. The factory default setting is none.