44
CONTROLLER INSTALLATION
INSTALLATION MANUAL
WALL INSTALLATION
1.
In the area of installation drill 2 holes with 6 mm in diameter, app. 40 mm deep.
Centres of holes must be 120 mm apart vertically.
Insert screws anchors. Screw the screw in the upper anchor in a way that approximate-
ly 4 mm of gap remains between the screw head and wall.
Install the regulator inside in a dry place, where it is not exposed to any strong electroma-
gnetic fields.
The controller is most common installed on the wall in the boiler room. Installation on the
wall is carried out according to the following procedure:
The SGC controllers are installed directly on the wall or on DIN rail or in the opening of
the solar group system.
1