Commissioning | Device Start
Doc. No. 982056, Version 01, SelectSun 40K
|
37
Only confirm the country code if you are absolutely sure it is correct.
If you are not sure, press
ESC
to cancel your selection and correct the selection.
If the country code is to be accepted, then confirm with
OK
.
A restart then takes place:
"ERROR" and "GROUND FAULT" status LEDs flash red alternately.
5.5
Device Start
Solar modules are irradiated with sufficient sunlight.
Country code is set.
Time and date is set.
The following procedure follows:
Self-test
All status LEDs are lit for approx. 6 seconds
Check
“START” status LED lights orange.
Activation
“START” status LED lights orange/LED “ON” flashes green.
Feed in
“ON” status LED lights green/normally all other status LEDs are off.
Set Country to
AR-N 4105 ?
Cancel OK
PAC
8260
W
VAC 405
V
VDC 634
V
E
da
y 27.6
k
W
h
Reboot
M
en
u
e