Safety Information | Protection against Contact with Hot Parts
Doc. No. 982056, Version 01, SelectSun 40K
|
11
2.6
Protection against Contact with Hot Parts
CAUTION
Danger of burns caused by hot surfaces on housings
At an ambient temperature of 45 °C, the upper part of the housing as well as the
refrigeration unit can reach a surface temperature of more than 75 °C.
Do not touch the housing surface near to heat sources.
Allow the device to cool down for 15 minutes before touching the surface of
the device.
2.7
Protection during Handling and Assembly
WARNING
Danger of injury during improper handling caused by crushing, shearing,
cutting, striking, and lifting
The weight of the inverter is 75.6 kg!
Follow the general setup and safety regulations for handling and assembly.
Use suitable assembly and transportation equipment.
Avoid trap and crush injuries by taking suitable precautions.
Only use suitable tools. Use special tools where this is prescribed.
Use lifting equipment and tools in a technically correct manner.
If necessary, use suitable protective equipment (for example, goggles, safety
footwear, protective gloves).
Do not stand under hanging loads.
Remove any liquids onto the floor immediately to avoid the danger of slipping.
2.8
Please Note Before Starting Up
•
In the event of installation in France, the device must be furnished with the warning sticker laid down by
UTE C 15-712-1. The warning stickers are included in delivery.
•
Problem-free and safe operation of the inverter is conditional upon due and specialized transportation,
storage, assembly and installation as well as careful operation and maintenance.
•
Only use accessories and spare parts approved by the manufacturer.
•
Adherence must be ensured to the prescriptions and stipulations regarding safety of the country in which
the inverter is to be used.
•
The ambient conditions stated in the product documentation must be observed.
•
In the planning and installation of the PV system, the technical design data, installation and safety of the
PV module manufacturer must be observed.
•
Starting up is prohibited until the entire system meets the national regulations and safety rules regarding
use.
•
Operation is only permitted with adherence to the national EMC prescriptions for the present use case.