MANUAL DE INSTRUCCIONES CODIGO 80188 REV E
Jun/2018
(Sujetas a modificaciones sin previo aviso) Pag.: 39
J
.P. SELECTA s.a.u.
Autovía A-2 Km 585.1 Abrera 08630 (Barcelona) España
Tel 34 937 700 877 Fax 34 937 702 362
e-mail: [email protected] - website: http://www.jpselecta.es
• Setting the dosing volume of NaOH
:
- Press
.
- Keep pressed keys
for a 10s until display shows dashes.
- Press
to select NaOH.
- Use
to set the NaOH pump working time
(factory setting 12).
- Use
to validate the setting.
- Press
to save the setting and exit from settings mode.
- Approximately each second means 5ml.
• Setting the dosing volume of Boric acid
:
- Press
.
- Keep pressed keys
for a 10s until display shows dashes.
- Press
to select H3BO3.
- Use
to set to set the Boric pump working time
(factory setting 4).
- Use
to validate the setting.
- Press
to save the setting and exit from the settings mode.
- Approximately each second means 10ml.
Status indication
1.
Heater ON
2.
Water feed fail.
3.
Safety door open or sample tube
not present.
4.
Overtemp on steam generator.
Display and selection keys.
5.
Display.
5.
Up/down keys.
Function keys.
6.
Operation function mode selection
between «Manual» and «Automa-
tic».
7. H3BO3 / START
«MANUAL» mode: Boric dose.
«AUTO» mode: cycle start.
8. NaOH
Modo «MANUAL»: NaOH dose.
Modo «AUTO»: No function.
9. STEAM
«MANUAL» mode: Distillation.
«AUTO» mode: No function.
10. EMPTY/STOP
«MANUAL» mode: Empty tube.
«AUTO» mode: STOP
Fig. 5.1 Control panel
6
1
3
2
7
8
4
5
9
10
5.4 MANUAL operation
• Select MANUAL mode. Key
toggles working mode. See Fig 5.1
• Set parameters according 5.3.
• Insert a sample tube (See 5.1) and an Erlenmeyer flask.
• Adding Boric
: Press
Boric acid will be added on the Erlenmeyer flask.
• Adding NaOH
: Press
NaOH will be added on the sample tube.