30
9.4) DOUBLER BOARD 15.14.376
DESCRIPTION
This board doubles the output voltage to optimise dynamic control of the arc and to ensure excellent arc striking in all welding conditions.
INSTRUMENTS REQUIRED
- Multimeter
- Set of pipe spanners for exagonal nuts
- Set of screwdrivers
BOARD
D1
Functional part
Generator/
Mode
Component
Test Point
Value
Type of
measure
Note
Diode
OFF
D1
A
K
+0.3Vdc
Note:
* Unless specified otherwise, all the measurements can suffer a var 10%