34
10.1 - POWER SUPPLY UNIT FAILED
OPERATION FLOW SIGNAL
The welding machine is connected to the 30Vac 50/60Hz single-phase mains. When the input switch is closed, phase and neutral are
connected to the welding logic and filter board 15.14.43. A varistor is connected between phase and neutral, i.e. a device protecting the
downstream electronics against overvoltages. In case of an overvoltage which is too high or lasts for too long, the varistor explodes.
The single-phase supply is filtered for electromagnetic compatibility purposes and is fed to board 15.14.44 for the AC/DC conversion. In
fact, power board 15.14.44 contains the rectifier bridge which allows a DC voltage of +35Vdc to be obtained.
BLOCK DIAGRAM