background image

8

4.2) ELECTROMAGNETIC COMPATIBILITY (EMC)

                                                    

                                               

                

CAUTION 

    

                 

This device is built in compliance with the indications contained in 

the harmonized standard EN60974-10, to which the operator must 

refer for the use of this apparatus.

-  lnstall and use the apparatus keeping to the instructions given in 

this manual.

-  This  device  must  be  used  for  professional  applications  only,  in 

industrial environments It is important to remember that it may 

be difficult to ensure the electromagnetic compatibility in other 

environments.

4.2.1 Installation, use and area examination

-   The user must be an expert in the sector and as such is respon-

sible for installation and use of the equipment according to the 

manufacturer’s instructions.

  lf any electromagnetic disturbance is noticed, the user must soave 

the problem, if necessary with the manufacturer’s technical assi-

stance.

-  In any case electromagnetic disturbances must be reduced until 

they are not a nuisance any longer.

-  Before installing this apparatus, the user must evaluate the poten-

tial electromagnetic problems that may arise in the surrounding 

area, considering in particular the health conditions of the per-

sons in the vicinity, for example of persons fitted with pacemakers 

or hearing aids.

4.2.2 Emission reduction methods

MAINS POWER SUPPLY

-  The  welding  power  source  must  be  connected  to  the  supply 

mains according to the manufacturer’s instructions.

In case of interference, it may be necessary to take further precau-

tions like the filtering of the mains power supply.

lt  is  also  necessary  to  consider  the  possibility  to  shield  the  power 

supply cable.

WELDING POWER SOURCE MAINTENANCE

The welding power source needs routine maintenance according to 

the manufacturer’s instructions.

When the equipment is working, all the access and operating doors 

and covers must be closed and fixed.

The welding power source must not be modified in any way.

WELDING AND CUTTING CABLES

The  welding  cables  must  be  kept  as  short  as  possible,  positioned 

near one another and laid at or approximately at ground level.

EQUIPOTENTIAL CONNECTION

The earth connection of all the metal component in the welding installa-

tion and near it must be taken in consideration.

However, the metal component connected to the workpiece will increa-

se the risk of electric shock for the operator, if he touches said metal 

component and the electrode at the same time.

Therefore, the operator must be insulated from all the earthed metal 

component. The equipotential connection must be made according to 

the national regulations.

EARTHING THE WORKPIECE

When the workpiece is  not earthed for electrical safety reasonsor 

due to its size and position, the earthing of the workpiece may re-

duce the emission. It is important to remember that the earthing of 

the workpiece should neither increase the risk of accidents for the 

operators, nor damage other electric equipment.

The earthing must be made according to the national regulations.

SHIELDING

The selective shielding of other cables and equipment present in the 

surrounding area may reduce the problems due to interference.

The shielding of the entire welding installation can be taken in con-

sideration for special applications.

4.2.3 RISK ANALYSIS

  

Risks posed by the machine

Solutions adopted to pervent 

them

Risk of wrong installation

A manual with the instructions 

for use has been produced

for this purpose

Electrical risks

Application of the EN 60974-1 / 

EN 60974-5 Standard

Risks  connected  with  electro-

magnetic  disturbances  produ-

ced by the welding power sour-

ce and induced on the welding 

power source.

Application  of  the  EN  60974-

10 Standard

Содержание GENESIS 145

Страница 1: ...REPAIRS MANUAL E N G L I S H Genesis 145...

Страница 2: ...icrofil ms are reserved and forbidden without the written authorisation of Selco S r l INDEX 1 PURSPOSE OF THE MANUAL PAG 3 2 WARNINGS PRECAUTIONS AND GENERAL NOTICES FOR PERFORMING REPAIRS PAG 4 3 IN...

Страница 3: ...any the machine The purchaser must follow the directions contained in the above manual Failure to do so will exempt Selco from all liability The operations described in this manual require the use of...

Страница 4: ...at high temperature CAUTION LIVE PARTS When handling internal parts of the machine remember that ope ning of the switch does not prevent the risk of electric shocks the machine must be unplugged from...

Страница 5: ...tween two points for example a b the arrow point indicates where to apply the red tip of the multimeter a while the black tip is applied at the other end b When a double arrow appears between two meas...

Страница 6: ...12Vdc 50A 14Vdc 100A 18Vdc 200A etc If output voltage goes too much above or below the rated value the generator could either saturate or go into arc force or other special features could be performe...

Страница 7: ...near it is pro tected with headphones or earphones 4 1 2 Fire explosion prevention The welding process may cause fires and or explosions Compressed gas cylinders are dangerous consult the supplier be...

Страница 8: ...rer s instructions When the equipment is working all the access and operating doors and covers must be closed and fixed The welding power source must not be modified in any way WELDING AND CUTTING CAB...

Страница 9: ...CE means that the average output current may be higher than that set S1 MMA TIG selection switch With the lever down it is in electrode welding MMA mode and thus the HOT START ARC FORCE and ANTI STICK...

Страница 10: ...uses with a 20A rating are required to be able to carry out 100 A electrode welding continuously and to make maximum use of the potential of the power source 16 A fuses are sufficient for welding with...

Страница 11: ...3 Hydrogen in weld present on electrode coating 5 6 2 Possible faults in the TIG welding Fault Cause Oxidations 1 lnsufficient gas 2 No protection on the rever se Tungsten inclusion 1 lncorrect elect...

Страница 12: ...ster switch b Varistor c EMI input filter board d Input rectifier e DC LINK capacitor f Power stage Forward converter g Power transformer h Output rectifier i Doubler j Output inductor k Primiry senso...

Страница 13: ...the persistence time exceeds certain limits the varistor is not capable of supporting this energy and burns out This happens for example as a result of overvoltages on the electric line or overvoltage...

Страница 14: ...of smoothing capacitors Thus the capacitor bank forms a DC LINK or a connection between the rectifier stage and the inverter stage on which a constant voltage difference is present The value of the D...

Страница 15: ...at the output current has the required dynamic range and the transformer does not become saturated The Forward converter made by Selco provides a suitable transfor mer resetting circuit in order to im...

Страница 16: ...uired to supply the various boards The electronic switch of the feeder is a MOSFET The functional wiring diagram of a multi output DC DC Flyback converter is illu strated in the figure below The weldi...

Страница 17: ...17 7 WIRING AND CONNECTION DIAGRAM...

Страница 18: ...18...

Страница 19: ......

Страница 20: ...U 2 Fase U dopo l interruttore Phase U after switch 4 Neutro N Neutral N 5 Neutro N dopo l interruttore Neutral N after switch 7 VBUS VBUS 8 GND_BUS GND_BUS 9 18Vdc 18Vdc 10 25Vdc 25Vdc 11 VSH VSH 12...

Страница 21: ...as a temperature alarm even if it is correctly supplied it does not release the power output For fast cooling leave the welding machine on in order to make use of the internal fan and thus reduce the...

Страница 22: ...the fault finding times and guides any subsequent action towards the damaged part In general the points to be visually checked are Input filter area Electrolytic smoothing capacitors Any traces of smo...

Страница 23: ...ntains the overcurrent protection devices varistor EMC filter circuitry the electronic welding logic and the switching power supply INSTRUMENTS REQUIRED Multimeter Set of screwdrivers BOARD CN1 L2 L1...

Страница 24: ...c 25Vdc LEDs ON L1 ON L2 ON 12Vdc power supply 12Vdc power supply Output voltage ON CN1 4 CN1 1 50Vdc 5Vdc Open Circuit Voltage MOSFET MF6 OFF S G S D 10kohm 0 5V Diode of the switching feeder OFF D23...

Страница 25: ...mer and to better the performance of the power stage INSTRUMENTS REQUIRED Multimeter Set of pipe spanners for exagonal nuts Set of screwdrivers BOARD L1 L2 MF1 MF2 MF5 K1 R11 1 R11 2 MF3 MF6 MF8 MF9 M...

Страница 26: ...c 10kohm Pre load relay ON RL1 D30 K A 24Vdc Listen to the preloading relay tripping with a time delay after switching on Relay supply voltage Power supply ON L1 ON L2 ON L3 ON when the welding machin...

Страница 27: ...upports 7 Fit the new diode bridge 8 Smear high temperature grease underneath the rectifier bridge and underneath the power devices MF1 MF2 MF3 MF4 MF6 MF7 MF8 MF9 9 Position the new sheet of SILPAD i...

Страница 28: ...the plastic support 5 Remove the sheet of SILPAD insulation which insulates the MOSFET MF5 WARNING The sheet of SILPAD insulation can NOT be re used 6 Clean any high temperature grease off the heat s...

Страница 29: ...r instruments required Multimeter Set of pipe spanners for exagonal nuts Set of screwdrivers BOARd NOTE Resistance R is not supplied with the 15 14 245 board If board 15 14 243 is replaced unsolder re...

Страница 30: ...0 4Vdc 0 4Vdc 0 4Vdc 0 4Vdc 0 4Vdc 0 4Vdc With board removed With board removed With board removed With board removed Diode OFF D5 A K 0 4Vdc Resistence R OFF R R 1 R 2 470ohm Notes Unless specified o...

Страница 31: ...e excellent arc striking in all welding conditions INSTRUMENTS REQUIRED Multimeter Set of pipe spanners for exagonal nuts Set of screwdrivers BOARD D1 Functional part Generator Mode Component Test Poi...

Страница 32: ...spanners for exagonal nuts Set of screwdrivers BOARD P2 P1 sw1 sw2 sw3 pt1 pt2 pt3 Functional part Generator mode Component Test Point Value Type of measure Note Switch OFF SW SW1 SW2 SW2 SW3 0ohm 0oh...

Страница 33: ...urrent value to 145 3A 9 7 SHUNT CHECK The current sensing is done by a shunt i e a bar of very low resistance made of constantan alloy through which the output current flows and a voltage drop propor...

Страница 34: ...ntify the description which is closest to the problem you have The problems are grouped into five sections 10 1 Power supply failed 10 2 Fan 10 3 Thermal alarm 10 4 Open circuit volatage 10 5 Power pa...

Страница 35: ...connected between phase and neutral i e a device protecting the downstream electronics against overvoltages In case of an overvoltage which is too high or lasts for too long the varistor explodes The...

Страница 36: ...pre sent Check the welder power supply and the sin gle phase rectifier bridge according to the procedure illustrated on page 25 The green and yellow LEDs lighten 1 Switching feeder in overload If the...

Страница 37: ...ssible problem Suggestions The fan will not start 1 Fan broken 2 15Vdc supply failure If the fan is correctly supplied by a voltage of 15Vdc but does not work replace the fan The 15Vdc supply voltage...

Страница 38: ...ggestions Machine in temperature alarm No problem Temperature device fault Logic fault The machine was working correctly and en tered into temperature alarm because the limit temperature was reached W...

Страница 39: ...e Zero no load voltage If the control system does not read the ou tput voltage the no load voltage rises consi derably about 100V In this case check that the red wire which reads the positive output v...

Страница 40: ...broken The forward converter can have some pro blems Check the rectifier bridge according to the procedure on page 25 If you must replace the rectifier bridge following the procedure on page 26 Chek t...

Страница 41: ...40 11 spare part list...

Страница 42: ...001 10 karte 15 14 243 11 Bus 49 02 79601 12 Elektrolytischer Kondensator 12 06 101 13 Diodenbr cke 14 10 150 14 Relais 09 09 026 15 Kit Leistungskarte 15 18 012 16 Ventilator 14 70 014 17 Kit Sekund...

Страница 43: ...3 25 electrode 110 A 40 13A Absorbed current with 4 00 electrode 140 A 40 17 8A Efficiency x 100 0 87 Power factor 0 7 Cos 0 99 Welding current x 35 x 60 x 100 145A 120A 100A Adjustment range 5 145A O...

Страница 44: ...43...

Страница 45: ...44 Selco s r l Via Palladio 19 35010 Onara di Tombolo Padova Italy Tel 39 049 9413111 Fax 39 049 9413311 e mail info selcoweld com...

Отзывы: