Selbit ISP-12F Скачать руководство пользователя страница 5

www.selbit.pl 

- 5 - 

 

Point -4 
 

Rotating encoder mounting 

 

   Added rotating encoder is designed to convert rotation of the head saw feeding screw for 
electrical impulses. Number of the impulses depends on screw pitch and this relation 
describes table 1. In most of the frame sawing machines this screw has got free tip where the 
encoder can be installed. Please make a concentric hole in the screw and mount encoder’s 
clutch.  Please make sure that this hole is concentric otherwise it can cause swinging and 
eventually incorrect encoder working and its damage. Please make hole around 15 mm and 
create thread M8. Next mount encoder using fixing band (fig.4). The band should be attached 
to the special fixing which because of the variety of the frame sawing machines should be 
created individually. Example of the encoder mounting is shown at the photo 4a below.  

 

Photo 4a. Example of the necoder mounting.                            Fig. 4 Encoder mounting ex ample. 
 

 
Table 1 
 

Screw pitch  

[mm./obr.] 

Encoder type 

[imp./rotation] 

Devider 

Rotating 42  

28 

Rotating 42  

21 

Rotating 50  

20 

Rotating 48  

16 

Rotating 42  

12 

Rotating 48  

12 

Linear  MB3200  

10 

Rotating 50  

10 

Chain  sawing frame machine 

Linear MSK  320 + MB 320 

 

Data from table 1 should be used during procedure of checking the controller’s 

parameters. 

 

   Cable connection of the encoder should be routed as far as it is possible from other electrical 
cables. Using special clip bands lead it to the place where the controller is mounted.   

 

Содержание ISP-12F

Страница 1: ...me machines ISP 12F Automatic thickness controller ISP 12F is designed to be mounted on the sawing frame machine Before assembly and start please read this handbook manual carefully instructions provi...

Страница 2: ...pter 12 Possible errors and solutions CHAPTER 1 Mounting and controller s connections During controller s mounting is advised to follow this instructions correctly Point 1 Before mounting in the main...

Страница 3: ...tric switch All cable connections should be made using special wires with double insulation oriented for use of the electric devices powered by 230V alternating current Cables should be rounded with d...

Страница 4: ...e power cubicle To the transformer s clips marked as SEC 24V please connect wires which feed electronic plate of the controller Analogically please place this wires as far as it is possible from other...

Страница 5: ...fixing band fig 4 The band should be attached to the special fixing which because of the variety of the frame sawing machines should be created individually Example of the encoder mounting is shown at...

Страница 6: ...each other creating two layers Sensor MSK 3200 should be mounted on not moveable part of the machine according to the controller to not create any cable movements which can cause its damage In case o...

Страница 7: ...the cable from the limit switches make sure that they are as far away as possible from other cables and power devices Remember that there is a specific time interval between the moment the limit switc...

Страница 8: ...eened control cable with a cross section adapted to the connection terminals The isolated ends of the individual conductors should be tightened in collets appropriate for the given cross section the u...

Страница 9: ...of the ATV 320 converter Prepared cables connections and casing assembly of the controller Please connect power cable TS 8 24 SEC 12 V with prepared cables tips to the junction marked as PWR on the co...

Страница 10: ...r s junction marked as IN 2 CAUTION Incorrect connection of the rotating or magnetic encoder may cause its serious damage Connection of TS18 05P 2 electronic limit switches Connect the limit switch re...

Страница 11: ...www selbit pl 11 Figure 9 Wiring diagram for manual remote control buttons Figure 10 Block diagram for MSK 320 magnetic encoder...

Страница 12: ...www selbit pl 12 Figure 11 Block diagram for rotary encoder...

Страница 13: ...sealing Next step in case the controller as a separate devise please mount it using four 4 1x10 screws on the sawing frame machine Screws should go though four holes in the back casing created for thi...

Страница 14: ...converter is not supplied with the adjuster a full configuration of functions should be made as described in all tables K 1 Setting of electrical parameters of the drive Input by ConF FULL Sin Functio...

Страница 15: ...ued Input by ConF FULL Fun PSS Function Value Description of the function PS2 LI3 Terminal DI3 triggers the set speed PS4 LI4 Terminal DI4 triggers the set speed SP2 10 Second set speed not used SP3 1...

Страница 16: ...ad lowering during vibrations occurring in the cutting process the recommended option is to install a drive brake with an electromagnetic release The application of this solution keeps the head fixed...

Страница 17: ...s on the display stop flashing The configuration that is currently loaded into the converter cannot be selected for saving For example if the converter is currently operating using the configuration n...

Страница 18: ...n in the Saw Height window should increase along with the upward movement of the head If the counter malfunctions i e the displayed value decreases when the head is moved up and increases during the d...

Страница 19: ...er s impulses to rotation ratio mounted on this machine is imp rot Next using table 1 from point 4 of this instruction check which divider is correct for this sawing frame machine Example for pitch sc...

Страница 20: ...ol of the saw trace and its value will be displayed Now there is a possibility to check and eventually change this value depends on the saw type used Typing in the saw trace please notice that the val...

Страница 21: ...end this operation If there will be a mistyping in providing the real value please wait 3 seconds and start again Please type in value as follow e g for giving 125 mm press 1 2 5 buttons Next please s...

Страница 22: ...saw over the cut material to allows it to return safely to the beginning of the processed material The lifting height of the saw in normal mode can be modified as follows Turn off the power supply of...

Страница 23: ...UP button the adjuster lifts the saw by 12 mm plus the last cut dimension In this mode after cutting another board you can return the head to the beginning of the track without removing the cut board...

Страница 24: ...ical use Controller takes into account trace of the saw cutting thickness displayed on the screen is real cutting value of produced material Next instructions describes cutting methods available in th...

Страница 25: ...scraped material from the track and press Saw UP button and return at the beginning of the main track While the controller set up the head saw there is a possibility to provide change thickness value...

Страница 26: ...tinue to provide all required position of the cutting When provided values exceeds head saw level provided position number when it is happening will be blinking At any moment during manual programming...

Страница 27: ...www selbit pl 27...

Страница 28: ...by the controller and text Pres Cut is displayed During providing the changes on the each positions those which can not be fit into are rejected by the controller If changes on the positions lower pos...

Страница 29: ...www selbit pl 29...

Страница 30: ...m first use A B or C holding for a while to call it out When the number is displayed please press and hold Exit Delete button and the text Clr confirms this operation and controller goes to normal mod...

Страница 31: ...recommendation For having maximal good parameters of the cutting it is recommended to use auto calibration at least twice a week Auto calibration proceedings are in details described in the point 3 of...

Страница 32: ...romagnetic compatibility directive The assembler of the controller ISP 12F is responsible for fulfil all those directives Product and equipment described within this instruction can be modify as from...

Страница 33: ...magnetic tape Check the connections of the control outputs of the adjuster with further electrical installation of the machine and the frequency converter 6 During auto calibration the adjuster stops...

Отзывы: