Selbit ISP-12F Скачать руководство пользователя страница 17

www.selbit.pl 

- 17 - 

 

For any additional information, please refer to the operating instructions of the ATV 
320 converter manufacturer. 
 
After fine-tuning of the parameters and checking the correctness of the operation of the 
adjuster cooperating with the converter, save the configuration made to the ATV 320 
memory so that it can be quickly restored if necessary. 
 
Custom settings should be saved in the converter memory in configuration number 2(Str2 

 

CFG2) 
Configuration number 1(CFG1
) contains pre-set settings supporting the ISP-12F adjuster 
but does not contain drive parameter values; it is only used for the initial configuration. 

 
 
 
 

Saving your custom configuration in the converter memory (Str2): 
rdy – ConF – FCS –  

 
Function 

Value 

Description of the function 

Fry- 

ALL 

When the message ALL is displayed, press the knob so that the two 
vertical bars on the right side of the display are displayed at the top 
and then press ESC
 

SCSI 

Str2 

Selected configuration set number 2. Press the knob and hold for> 3s 
until the dots on the display stop flashing 

 

The configuration that is currently loaded into the converter cannot be selected for 
saving. For example, if the converter is currently operating using the configuration 
number 1, then you can only select configuration number 2 or restore factory settings 
(InI). 

 

 
Recovering a previously saved configuration from the machine's memory, (CFG2):  
rdy – ConF – FCS –  

 
 
Function 

Value 

Description of the function 

FCSI 

CFG2 

Selected restore factory configuration 

Fry- 

ALL 

When the message ALL is displayed, press the knob so that the two 
vertical bars on the right side of the display are displayed at the top 
and then press ESC
 

GFS 

YES 

After changing the message to YES, press and hold the knob for > 2s 
until the dots on the display stops flashing 

 

If the converter is supplied with the ISP-12F adjuster, you can restore the initial 
configuration as described above by selecting the CFG1 name in the FCSI function. 
 
 
Restoring factory settings of the ATV 320 converter 
 
If necessary, you can restore the factory settings (it does not include the initial 
configurations for the ISP-12F adjuster) 
After restoring the factory settings, set all the required parameters according to the 
operating instructions! 
 

Содержание ISP-12F

Страница 1: ...me machines ISP 12F Automatic thickness controller ISP 12F is designed to be mounted on the sawing frame machine Before assembly and start please read this handbook manual carefully instructions provi...

Страница 2: ...pter 12 Possible errors and solutions CHAPTER 1 Mounting and controller s connections During controller s mounting is advised to follow this instructions correctly Point 1 Before mounting in the main...

Страница 3: ...tric switch All cable connections should be made using special wires with double insulation oriented for use of the electric devices powered by 230V alternating current Cables should be rounded with d...

Страница 4: ...e power cubicle To the transformer s clips marked as SEC 24V please connect wires which feed electronic plate of the controller Analogically please place this wires as far as it is possible from other...

Страница 5: ...fixing band fig 4 The band should be attached to the special fixing which because of the variety of the frame sawing machines should be created individually Example of the encoder mounting is shown at...

Страница 6: ...each other creating two layers Sensor MSK 3200 should be mounted on not moveable part of the machine according to the controller to not create any cable movements which can cause its damage In case o...

Страница 7: ...the cable from the limit switches make sure that they are as far away as possible from other cables and power devices Remember that there is a specific time interval between the moment the limit switc...

Страница 8: ...eened control cable with a cross section adapted to the connection terminals The isolated ends of the individual conductors should be tightened in collets appropriate for the given cross section the u...

Страница 9: ...of the ATV 320 converter Prepared cables connections and casing assembly of the controller Please connect power cable TS 8 24 SEC 12 V with prepared cables tips to the junction marked as PWR on the co...

Страница 10: ...r s junction marked as IN 2 CAUTION Incorrect connection of the rotating or magnetic encoder may cause its serious damage Connection of TS18 05P 2 electronic limit switches Connect the limit switch re...

Страница 11: ...www selbit pl 11 Figure 9 Wiring diagram for manual remote control buttons Figure 10 Block diagram for MSK 320 magnetic encoder...

Страница 12: ...www selbit pl 12 Figure 11 Block diagram for rotary encoder...

Страница 13: ...sealing Next step in case the controller as a separate devise please mount it using four 4 1x10 screws on the sawing frame machine Screws should go though four holes in the back casing created for thi...

Страница 14: ...converter is not supplied with the adjuster a full configuration of functions should be made as described in all tables K 1 Setting of electrical parameters of the drive Input by ConF FULL Sin Functio...

Страница 15: ...ued Input by ConF FULL Fun PSS Function Value Description of the function PS2 LI3 Terminal DI3 triggers the set speed PS4 LI4 Terminal DI4 triggers the set speed SP2 10 Second set speed not used SP3 1...

Страница 16: ...ad lowering during vibrations occurring in the cutting process the recommended option is to install a drive brake with an electromagnetic release The application of this solution keeps the head fixed...

Страница 17: ...s on the display stop flashing The configuration that is currently loaded into the converter cannot be selected for saving For example if the converter is currently operating using the configuration n...

Страница 18: ...n in the Saw Height window should increase along with the upward movement of the head If the counter malfunctions i e the displayed value decreases when the head is moved up and increases during the d...

Страница 19: ...er s impulses to rotation ratio mounted on this machine is imp rot Next using table 1 from point 4 of this instruction check which divider is correct for this sawing frame machine Example for pitch sc...

Страница 20: ...ol of the saw trace and its value will be displayed Now there is a possibility to check and eventually change this value depends on the saw type used Typing in the saw trace please notice that the val...

Страница 21: ...end this operation If there will be a mistyping in providing the real value please wait 3 seconds and start again Please type in value as follow e g for giving 125 mm press 1 2 5 buttons Next please s...

Страница 22: ...saw over the cut material to allows it to return safely to the beginning of the processed material The lifting height of the saw in normal mode can be modified as follows Turn off the power supply of...

Страница 23: ...UP button the adjuster lifts the saw by 12 mm plus the last cut dimension In this mode after cutting another board you can return the head to the beginning of the track without removing the cut board...

Страница 24: ...ical use Controller takes into account trace of the saw cutting thickness displayed on the screen is real cutting value of produced material Next instructions describes cutting methods available in th...

Страница 25: ...scraped material from the track and press Saw UP button and return at the beginning of the main track While the controller set up the head saw there is a possibility to provide change thickness value...

Страница 26: ...tinue to provide all required position of the cutting When provided values exceeds head saw level provided position number when it is happening will be blinking At any moment during manual programming...

Страница 27: ...www selbit pl 27...

Страница 28: ...by the controller and text Pres Cut is displayed During providing the changes on the each positions those which can not be fit into are rejected by the controller If changes on the positions lower pos...

Страница 29: ...www selbit pl 29...

Страница 30: ...m first use A B or C holding for a while to call it out When the number is displayed please press and hold Exit Delete button and the text Clr confirms this operation and controller goes to normal mod...

Страница 31: ...recommendation For having maximal good parameters of the cutting it is recommended to use auto calibration at least twice a week Auto calibration proceedings are in details described in the point 3 of...

Страница 32: ...romagnetic compatibility directive The assembler of the controller ISP 12F is responsible for fulfil all those directives Product and equipment described within this instruction can be modify as from...

Страница 33: ...magnetic tape Check the connections of the control outputs of the adjuster with further electrical installation of the machine and the frequency converter 6 During auto calibration the adjuster stops...

Отзывы: