Magnetic encoder’s connection MSK-320 in chain sawing frame machine:
Magnetic encoder cables please connect with junctions marked ENCODER as follow:
-
brown cable of MSK-320 with controller’s junction marked as (+24) plus
-
black cable of MSK-320 with controller’s junction marked as (GND) minus
-
red cable of MSK-320 with controller’s junction marked as IN-1
-
orange cable of MSK-320 with controller’s junction marked as IN-2
CAUTION!!!
Incorrect connection of the rotating or magnetic encoder may cause its serious damage!!
Connection of TS18-05P-2 electronic limit switches:
Connect the limit switch restricting the downward movement to the MPS-DWN connector of
the adjuster:
- brown to con24
- blue to connector GND
- black for connector IN
Similarly, connect the limit switch restricting the upward movement, this time to the MPS-UP
connector.
Instead of electronic you can use electromechanical switches and connect them as shown in
the figure.
Figure 8
Wiring diagram for electromechanical limit switches