Next step after creating all of the connections is assembly of the controller’s casing. Before
connecting from panel with the back side please check if the rubber sealing is in the special
groove. It is important in regarding sealing and protecting controller’s main electronic plate
from any contamination. After put the from panel in together with the back side please screw
casing using included six screws 4,1x12. Before mounting the controller on the machine it is
recommended to checking of proper controller’s operating according to “first start” chapter
(2). After checking of the controller’s proper operating please use safety plugs in the places
where screws are and mount the controller on the machine. Controller’s mounting in the main
machine’s board is analogical, there is only one difference that front panel is screwed from
the inside with plastic frame and main panel casing. After all mounting please carefully pull
out cables which go out at the back side of the controller’s casing to reduce their unnecessary
length in the inside. Please be careful to not destroy any connection. After this operation
please screw PG choke to create proper sealing. Next step, in case the controller as a separate
devise, please mount it using four 4,1x10 screws on the sawing frame machine. Screws should
go though four holes in the back casing created for this purpose.
Chapter 2
First-time start-up
Some of the converter settings must be adapted to your drive before operation
(parameters of the head feed motor, moment of inertia of the drive and related
acceleration and deceleration ramp times).
Attention!
The configuration of the adjuster requires basic technical knowledge related to the
practical application of the said devices and should be performed by a person with
appropriate professional qualifications.
Correct configuration requires the exact programming sequence K1-K9!
Programming the frequency converter.
Attention!
Programming of the frequency converter parameters should be performed while it is
turned on but not executing control commands and the display shows the message "rdy"
The time parameters of the acceleration and deceleration ramp should be selected
depending on the weight of the moving parts of the machine head drive and the travel
speed of the drive.
In order to optimize the stopping time of the head, appropriate brake resistors should be
used, matching the performance of the frequency converter.
When determining ramp times, make sure that they are not too small in relation to the
machine's inertia.