I‑5039
35
(3) Connection with sports printer (CT-1000/916) (standard operating mode)
(a) Setting
Set the FUNCTION switch at 20 .
Turn the POWER switch to ON.
(b) Cabling
< Where signal distribution box (ST-22) is used >
Two units of ST-306 can be connected.
The two units of ST-306 display the time data of CT-1000/916 in perfect synchronism.
(c) Operation
Start/split/lap/finish signals for MODEL ST-306 are all controlled automatically by CT-1000/916.
When the MODEL ST-306 is connected with CT-1000/916, the buzzer in the ST-306 will not beep.
(d) Display data
The running time is displayed at all times.
When a player has reached the finish line, the sports timer will display finish time for about 5
seconds and then return to the running time display mode.
When other players have arrived the finish line during said 5-second period, their finish times will not
be displayed.
The display pattern is determined by the RANGE settings of CT-1000/916 and ST-306 as follows.
ST-306
CT-1000/916
1/100 1/10
1
1/100
1/10
1
Inhibited (because the display accuracy preposterously becomes higher than the
measuring accuracy.)
ST-306
Cable terminated to
GRIP/EXT. connector
Sports printer
CT-1000/916
Cable (option)
ST-306
Cable terminated to
GRIP/EXT. connector
Sports Printer
CT-1000/916
Cable (option)
ST-306
Cable terminated to
GRIP/EXT. connector
Cable 10m (option)
Signal distribution box
ST-22