INSTALLATION (Cont.)
MINIMUM CLEARANCES
Walls or vertical structures must be at least 200mm away from the burner.
Where the horizontal clearance is less than 200mm, that vertical surface must be
protected by a non-combustible material for 150mm above the cooktop surface
across the entire length (depth, width). The 150mm protected surface may be
ceramic tiles or another approved non-combustible material.
The combustable surface within the clearance zone may be protected by one of
the following methods.
a.
Fixing ceramic tiles with a minimum thickness of 5mm to the surface.
b.
Fixing toughened glass with a minimum thickness of 5mm to the surface,
provided the glass is approved by the manufacturer to be suitable for
the appliacation.
c.
Attaching fire resistant material to the surface and covering with sheet
metal with a minimum thickness of 0.4mm
There must be a minimum clearance of 50mm between the base of the appliance
and a combustible surface.