15
ELECTRICAL CONNECTION
• Insert the powerplug firmly into an appropriate power outlet and switch it on.
• The power outlet must be correctly earthed and easily accessible.
The outlet voltage and frequency must cirrespond to the voltage indicated
on the appliance taing label.
• All electrical work is to be carried out by a qualified/licenced electrician,
COMMISSIONING
The below must be performed on the Gas Cooktop by an authorised installer
before leaving;
• The Gas Regulator supplied is non-adjustable, to check operation turn on
and light the Rapid Burner only.
• Measure and confirm the Test point pressure is 1KPa.
FINAL CHECKS
Once commissioning is done and before leaving, the installer must check:
• Gas supply has no leaks, using soap and water solution.
• Every part (knobs, trivets, burners) and the gas pipe are installed properly.
• Ingnition system is working correctly with all burners, individually and all at
the same time.
• As each burner is lit, it produces a well defined blue flame with no yellow
tipping.
• Burner flame remains lit when rotating control knob from Maximum to
minimum flame quickly.
• Check that the ignition system is functioning on all burners both individually
and combined.
INSTALLATION (Cont.)